Achieving Improved Ion Swarm Shaping Based on Ion Leakage Control in Ion Mobility Spectrometry

In Ion Mobility Spectrometry (IMS), ion gates are essential for controlling ion flow, significantly impacting detection sensitivity and resolution. Despite various optimization methods, a clear approach is needed to define the performance limits of ion gates. This study proposes a linear relationship between peak intensity (<i>I</i><sub>p</sub>) and resolving power (<i>R</i><sub>p</sub>) at low ion quantities, introducing it as a reference for evaluating the optimization level. The Tri-State gate (TSG) enables the accurate study of this <i>I</i><sub>p</sub>-<i>R</i><sub>p</sub> relationship, but ion leakage of TSG disrupts control over narrow ion swarms, thereby limiting <i>R</i><sub>p</sub>. After the causes of ion leakage were examined, a preshaping method that removes the gate-opening phase was proposed to precisely control ion injection. This method leverages ion leakage to improve <i>R</i><sub>p</sub> while ensuring the linearity between <i>I</i><sub>p</sub> and <i>R</i><sub>p</sub>. The preserved linearity means avoiding excessive ion loss and shape distortion, ultimately leading to optimal resolving power. Simulations and experiments demonstrate that precise voltage adjustments effectively minimize ion leakage, enhancing resolving power by 50% (reaching a maximum of 106), while the corresponding decrease in signal intensity follows the <i>I</i><sub>p</sub>-<i>R</i><sub>p</sub> linear relationship. This approach expands the accessible range of <i>I</i><sub>p</sub>-<i>R</i><sub>p</sub> combinations without altering their fundamental relationship, reduces discrimination, and establishes a new evaluation method for optimizing ion gate performance in IMS.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-04-23
DOI
https://doi.org/10.1021/acs.analchem.4c05889
Citations
2
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.51

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Achieving Improved Ion Swarm Shaping Based on Ion Leakage Control in Ion Mobility Spectrometry

Ruina Zhang, Kai Ni, Shihao Li, Jiyao Wang et al.
2 citations
Analytical Chemistry
Mass Spectrometry Techniques and Applications
1.51
article

Achieving Improved Ion Swarm Shaping Based on Ion Leakage Control in Ion Mobility Spectrometry

Ruina Zhang, Kai Ni, Shihao Li, Jiyao Wang, Boyu Du, Xiaohao Wang
article en
2 citations

Abstract

In Ion Mobility Spectrometry (IMS), ion gates are essential for controlling ion flow, significantly impacting detection sensitivity and resolution. Despite various optimization methods, a clear approach is needed to define the performance limits of ion gates. This study proposes a linear relationship between peak intensity (<i>I</i><sub>p</sub>) and resolving power (<i>R</i><sub>p</sub>) at low ion quantities, introducing it as a reference for evaluating the optimization level. The Tri-State gate (TSG) enables the accurate study of this <i>I</i><sub>p</sub>-<i>R</i><sub>p</sub> relationship, but ion leakage of TSG disrupts control over narrow ion swarms, thereby limiting <i>R</i><sub>p</sub>. After the causes of ion leakage were examined, a preshaping method that removes the gate-opening phase was proposed to precisely control ion injection. This method leverages ion leakage to improve <i>R</i><sub>p</sub> while ensuring the linearity between <i>I</i><sub>p</sub> and <i>R</i><sub>p</sub>. The preserved linearity means avoiding excessive ion loss and shape distortion, ultimately leading to optimal resolving power. Simulations and experiments demonstrate that precise voltage adjustments effectively minimize ion leakage, enhancing resolving power by 50% (reaching a maximum of 106), while the corresponding decrease in signal intensity follows the <i>I</i><sub>p</sub>-<i>R</i><sub>p</sub> linear relationship. This approach expands the accessible range of <i>I</i><sub>p</sub>-<i>R</i><sub>p</sub> combinations without altering their fundamental relationship, reduces discrimination, and establishes a new evaluation method for optimizing ion gate performance in IMS.

Analytical ChemistryVol. 97(17)
Tsinghua–Berkeley Shenzhen Institute (CN), Institute of Advanced Manufacturing Technology (CN), Tsinghua University (CN)
National Natural Science Foundation of China, Shenzhen Fundamental Research Program
Affordable and clean energy
Openalex Percentile: Top 19%
Mass Spectrometry Techniques and Applications
1.51
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.