On-Chip $\mathbf{G}{{\mathbf{e}}_{1 - {\bm{x}}}}\mathbf{S}{{\mathbf{n}}_{\bm{x}}}$ Slot Optical Waveguides-Based Highly Sensitive Mid-Infrared Biochemical Sensors for Room Temperature Applications

In this work, we present the first proof of complementary metal-oxide-semiconductor (CMOS)-compatible GeSn slot optical waveguides (WGs)-based highly-sensitive biochemical sensors for mid-infrared (MIR) applications. Moreover, proposed WGs are designed to achieve high sensitivity values in the MIR region, specifically at 3.67 μm for lipids detection. The simulation indicates that GeSn core height and width affect the confinement factor significantly in both the sensing and slot regions. In an optimized WG geometry (H = W = 300 nm), the proposed cross-slot waveguide (CS-WG) demonstrates the highest confinement factors of 43% and 50% in the slot and sensing regions, respectively, notably higher than the values obtained for the designed vertical-slot-WG and horizontal-slot-WG. Subsequently, the WG sensitivity is determined by taking into account the impact of changes in the thickness of the sensing layer. The results indicate that a biochemical sensor utilizing a cross-slot WG demonstrates the highest sensitivity compared to biochemical sensors based on either horizontal-slot or vertical-slot WGs. Furthermore, the CS-WG MIR sensor we propose demonstrates the sensitivity value of 2.8 × 10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-3</sup> nm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup>, which is one order of magnitude higher than the sensitivity value of 4 × 10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-4</sup> nm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> achieved by the earlier reported Si slot SWIR WG sensor. This comparison highlights the efficacy of our proposed biochemical sensors for MIR sensing applications.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Letters
Published
2025-04-23
DOI
https://doi.org/10.1109/lsens.2025.3563778
Primary Topic
Photonic and Optical Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On-Chip $\mathbf{G}{{\mathbf{e}}_{1 - {\bm{x}}}}\mathbf{S}{{\mathbf{n}}_{\bm{x}}}$ Slot Optical Waveguides-Based Highly Sensitive Mid-Infrared Biochemical Sensors for Room Temperature Applications

Harshvardhan Kumar, Jyotiprakash B. Yadav, Neha Soni
4 links
IEEE Sensors Letters
Photonic and Optical Devices
article

On-Chip $\mathbf{G}{{\mathbf{e}}_{1 - {\bm{x}}}}\mathbf{S}{{\mathbf{n}}_{\bm{x}}}$ Slot Optical Waveguides-Based Highly Sensitive Mid-Infrared Biochemical Sensors for Room Temperature Applications

Harshvardhan Kumar, Jyotiprakash B. Yadav, Neha Soni
article en

Abstract

In this work, we present the first proof of complementary metal-oxide-semiconductor (CMOS)-compatible GeSn slot optical waveguides (WGs)-based highly-sensitive biochemical sensors for mid-infrared (MIR) applications. Moreover, proposed WGs are designed to achieve high sensitivity values in the MIR region, specifically at 3.67 μm for lipids detection. The simulation indicates that GeSn core height and width affect the confinement factor significantly in both the sensing and slot regions. In an optimized WG geometry (H = W = 300 nm), the proposed cross-slot waveguide (CS-WG) demonstrates the highest confinement factors of 43% and 50% in the slot and sensing regions, respectively, notably higher than the values obtained for the designed vertical-slot-WG and horizontal-slot-WG. Subsequently, the WG sensitivity is determined by taking into account the impact of changes in the thickness of the sensing layer. The results indicate that a biochemical sensor utilizing a cross-slot WG demonstrates the highest sensitivity compared to biochemical sensors based on either horizontal-slot or vertical-slot WGs. Furthermore, the CS-WG MIR sensor we propose demonstrates the sensitivity value of 2.8 × 10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-3</sup> nm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup>, which is one order of magnitude higher than the sensitivity value of 4 × 10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-4</sup> nm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> achieved by the earlier reported Si slot SWIR WG sensor. This comparison highlights the efficacy of our proposed biochemical sensors for MIR sensing applications.

IEEE Sensors LettersVol. 9(5)
National Institute of Technology Warangal (IN), LNM Institute of Information Technology (IN)
Affordable and clean energy
Openalex Percentile: Top 93%
Photonic and Optical Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.