Normalised Diagnostic Contribution Index (NDCI) Integration to Multi Objective Sensor Optimisation Framework (MOSOF)—An Environmental Control System Case

In modern aerospace systems, effective sensor optimisation is essential for ensuring reliable diagnostics, efficient resource allocation, and proactive maintenance. This paper presents Normalised Diagnostic Contribution Index (NDCI) integration into the Multi-Objective Sensor Optimisation Framework (MOSOF) to address application-specific performance nuances. Building on previous work, the proposed approach leverages a multi-objective genetic algorithm to optimise key criteria, including performance, cost, reliability management, and compatibility. NDCI is derived from simulation data obtained via the Boeing 737-800 Environmental Control System (ECS) using the SESAC platform, where degradation level readings across four fault modes are analysed. The framework evaluates sensor performance from the perspectives of Original Equipment Manufacturers (OEM), Airlines, and Maintenance Repair Overhaul (MRO) organisations. Validation against the Minimum Redundancy Maximum Relevance (mRMR) method highlights the distinct advantage of NDCI by identifying an optimal set of three sensors compared to mRMR's six-sensor solution, and MOSOF's multi-objective insertion enhances sensor deployment for different stakeholders. This integration not only expands the feasible solution space for sensor-pair configurations but also emphasises diagnostic value over redundancy. Overall, the enhanced NDCI-MOSOF offers a scalable, multi-stakeholder approach for next-generation sensor optimisation and predictive maintenance in complex aerospace systems. The results demonstrate significant improvements in diagnostics efficiency for stakeholders.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-04-23
DOI
https://doi.org/10.3390/s25092661
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Normalised Diagnostic Contribution Index (NDCI) Integration to Multi Objective Sensor Optimisation Framework (MOSOF)—An Environmental Control System Case

Fakhre Ali, Ian Jennions, Burak Suslu
Sensors
Fault Detection and Control Systems
article

Normalised Diagnostic Contribution Index (NDCI) Integration to Multi Objective Sensor Optimisation Framework (MOSOF)—An Environmental Control System Case

Fakhre Ali, Ian Jennions, Burak Suslu
article en

Abstract

In modern aerospace systems, effective sensor optimisation is essential for ensuring reliable diagnostics, efficient resource allocation, and proactive maintenance. This paper presents Normalised Diagnostic Contribution Index (NDCI) integration into the Multi-Objective Sensor Optimisation Framework (MOSOF) to address application-specific performance nuances. Building on previous work, the proposed approach leverages a multi-objective genetic algorithm to optimise key criteria, including performance, cost, reliability management, and compatibility. NDCI is derived from simulation data obtained via the Boeing 737-800 Environmental Control System (ECS) using the SESAC platform, where degradation level readings across four fault modes are analysed. The framework evaluates sensor performance from the perspectives of Original Equipment Manufacturers (OEM), Airlines, and Maintenance Repair Overhaul (MRO) organisations. Validation against the Minimum Redundancy Maximum Relevance (mRMR) method highlights the distinct advantage of NDCI by identifying an optimal set of three sensors compared to mRMR's six-sensor solution, and MOSOF's multi-objective insertion enhances sensor deployment for different stakeholders. This integration not only expands the feasible solution space for sensor-pair configurations but also emphasises diagnostic value over redundancy. Overall, the enhanced NDCI-MOSOF offers a scalable, multi-stakeholder approach for next-generation sensor optimisation and predictive maintenance in complex aerospace systems. The results demonstrate significant improvements in diagnostics efficiency for stakeholders.

SensorsVol. 25(9)
Cranfield University (GB)
Openalex Percentile: Top 91%
Fault Detection and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.