TD-ESI-MS/MS for High-Throughput Screening of 13 Common Drugs and 4 Etomidate Analogs in Hair: Method Validation and Forensic Applications

This study established a dual analytical workflow integrating thermal desorption-electrospray ionization-tandem mass spectrometry (TD-ESI-MS/MS) for rapid qualitative screening and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) for confirmatory quantification of 17 psychoactive substances and metabolites across six classes (opioids, amphetamine-type stimulants, cocaine, ketamine-type drugs, cannabinoids, and etomidate analogs) in hair matrices. Validation of the TD-ESI-MS/MS method demonstrated its sensitivity (limits of detection: 0.1-0.2 ng/mg) and precision (<19.3%), with matrix effects controlled to <19.6%. The TD-ESI-MS/MS method achieved an analysis time of 1 min per sample, enabling high-throughput screening with a sensitivity >85.7% and a specificity >89.7% for the 17 analytes. UPLC-MS/MS confirmation validated the screening results with accuracy rates of 89.7-99.8%. An analysis of specimens confirmed positive identified etomidate analogs as the predominant psychoactive substances (73.6%), with a lower prevalence of amphetamine-type stimulants (12.5%), ketamine-type drugs (9.0%), and opioids (2.8%). The polydrug use patterns identified concurrent etomidate-amphetamine consumption (<i>n</i> = 5) and complex analog combinations (etomidate-isopropoxate-metomidate, <i>n</i> = 13), suggesting evolving abuse trends. Despite limitations in the temporal resolution and representativeness of the cohort, this study demonstrated the viability of TD-ESI-MS/MS for bridging forensic and public health priorities. Future work should focus on optimizing the durability of the ion source for TD-ESI and validating this method across diverse populations to enhance its generalizability.

Authors

Institutions

Publication Details

Journal
Toxics
Published
2025-04-23
DOI
https://doi.org/10.3390/toxics13050329
Primary Topic
Forensic Toxicology and Drug Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

TD-ESI-MS/MS for High-Throughput Screening of 13 Common Drugs and 4 Etomidate Analogs in Hair: Method Validation and Forensic Applications

Binling Zhu, Meng Li, Jinbo Li
Toxics
Forensic Toxicology and Drug Analysis
article

TD-ESI-MS/MS for High-Throughput Screening of 13 Common Drugs and 4 Etomidate Analogs in Hair: Method Validation and Forensic Applications

Binling Zhu, Meng Li, Jinbo Li
article en

Abstract

This study established a dual analytical workflow integrating thermal desorption-electrospray ionization-tandem mass spectrometry (TD-ESI-MS/MS) for rapid qualitative screening and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) for confirmatory quantification of 17 psychoactive substances and metabolites across six classes (opioids, amphetamine-type stimulants, cocaine, ketamine-type drugs, cannabinoids, and etomidate analogs) in hair matrices. Validation of the TD-ESI-MS/MS method demonstrated its sensitivity (limits of detection: 0.1-0.2 ng/mg) and precision (<19.3%), with matrix effects controlled to <19.6%. The TD-ESI-MS/MS method achieved an analysis time of 1 min per sample, enabling high-throughput screening with a sensitivity >85.7% and a specificity >89.7% for the 17 analytes. UPLC-MS/MS confirmation validated the screening results with accuracy rates of 89.7-99.8%. An analysis of specimens confirmed positive identified etomidate analogs as the predominant psychoactive substances (73.6%), with a lower prevalence of amphetamine-type stimulants (12.5%), ketamine-type drugs (9.0%), and opioids (2.8%). The polydrug use patterns identified concurrent etomidate-amphetamine consumption (<i>n</i> = 5) and complex analog combinations (etomidate-isopropoxate-metomidate, <i>n</i> = 13), suggesting evolving abuse trends. Despite limitations in the temporal resolution and representativeness of the cohort, this study demonstrated the viability of TD-ESI-MS/MS for bridging forensic and public health priorities. Future work should focus on optimizing the durability of the ion source for TD-ESI and validating this method across diverse populations to enhance its generalizability.

ToxicsVol. 13(5)
Guangdong Police College (CN)
Openalex Percentile: Top 92%
Forensic Toxicology and Drug Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

TD-ESI-MS/MS for High-Throughput Screening of 13 Common Drugs and 4 Etomidate Analogs in Hair: Method Validation and Forensic Applications — Binling Zhu, Meng Li, et al. · Toxics (2025) | TGRS Research Map | TGRS