The Usefulness of the Lateral Femoral Epicondyle as a Landmark for Evaluating Leg Length Discrepancy in Robot-Assisted Total Hip Arthroplasty

<b>Objective</b>: One of the biggest advantages of robot-assisted hip replacement surgery is the reduction in dislocation rates because of proper implant positioning and accurate measurement of the leg length. Therefore, we aimed to investigate the usefulness of using the lateral epicondyle as a landmark to minimize errors in leg length measurement. <b>Methods</b>: This retrospective study was conducted between September 2023 and March 2025 and included 24 patients who underwent robotic-assisted total hip arthroplasty (rTHA, Group I). These procedures were performed by two experienced surgeons. The data were compared with results from two additional groups: patients who underwent rTHA using the intrapatella landmark (Group II) and those who underwent conventional total hip arthroplasty (cTHA) without robotic assistance (Group III). Leg length measurements were evaluated using postoperative X-rays and intraoperative robotic monitoring. ANOVA and Student's <i>t</i>-test were used to analyze the significance of the variables (<i>p</i> < 0.05). <b>Results</b>: The mean X-ray LLD (xLLD) was 1.39 mm (-7.43-11.63 mm) and Mako LLD (mLLD) was 4.77 mm (-6-12 mm) in Group I. The mean xLLD was 3.54 mm (-5.02-13.6 mm) and mLLD was 4.20 mm (-22-14 mm) in Group II. The mean xLLD was 4.06 mm (-8.62-21.2 mm) in Group III. There was no statistical significance between the three groups (<i>p</i> = 0.241). <b>Conclusions</b>: Using the lateral femoral epicondyle as a landmark for the limb length measurement is a viable alternative to the intrapatella landmark in rTHA. This method may save time and offer and more convenient technique in measuring leg length changes during robotic-assisted total hip arthroplasty.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-04-23
DOI
https://doi.org/10.3390/jcm14092905
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Usefulness of the Lateral Femoral Epicondyle as a Landmark for Evaluating Leg Length Discrepancy in Robot-Assisted Total Hip Arthroplasty

Su-Chan Lee, Jihyo Hwang, Suengryol Ryu, Ji‐Hoon Baek et al.
Journal of Clinical Medicine
Orthopaedic implants and arthroplasty
article

The Usefulness of the Lateral Femoral Epicondyle as a Landmark for Evaluating Leg Length Discrepancy in Robot-Assisted Total Hip Arthroplasty

Su-Chan Lee, Jihyo Hwang, Suengryol Ryu, Ji‐Hoon Baek, D.W. Lee, Changhyun Nam, Taehyeon Kim
article en

Abstract

<b>Objective</b>: One of the biggest advantages of robot-assisted hip replacement surgery is the reduction in dislocation rates because of proper implant positioning and accurate measurement of the leg length. Therefore, we aimed to investigate the usefulness of using the lateral epicondyle as a landmark to minimize errors in leg length measurement. <b>Methods</b>: This retrospective study was conducted between September 2023 and March 2025 and included 24 patients who underwent robotic-assisted total hip arthroplasty (rTHA, Group I). These procedures were performed by two experienced surgeons. The data were compared with results from two additional groups: patients who underwent rTHA using the intrapatella landmark (Group II) and those who underwent conventional total hip arthroplasty (cTHA) without robotic assistance (Group III). Leg length measurements were evaluated using postoperative X-rays and intraoperative robotic monitoring. ANOVA and Student's <i>t</i>-test were used to analyze the significance of the variables (<i>p</i> < 0.05). <b>Results</b>: The mean X-ray LLD (xLLD) was 1.39 mm (-7.43-11.63 mm) and Mako LLD (mLLD) was 4.77 mm (-6-12 mm) in Group I. The mean xLLD was 3.54 mm (-5.02-13.6 mm) and mLLD was 4.20 mm (-22-14 mm) in Group II. The mean xLLD was 4.06 mm (-8.62-21.2 mm) in Group III. There was no statistical significance between the three groups (<i>p</i> = 0.241). <b>Conclusions</b>: Using the lateral femoral epicondyle as a landmark for the limb length measurement is a viable alternative to the intrapatella landmark in rTHA. This method may save time and offer and more convenient technique in measuring leg length changes during robotic-assisted total hip arthroplasty.

Journal of Clinical MedicineVol. 14(9)
Hallym University (KR), Himchan Hospital (KR), Hallym University Kangnam Sacred Heart Hospital (KR)
Openalex Percentile: Top 86%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.