Analysis of The Effect of Load Changes on The Performance of Synchronous Generator Unit 2 at PT. PLN Nusa Daya Unit PLTU Malinau

Changes in generator power losses are adjusted to the load needs in the field, which is constantly changing and can affect the value of the per- phase current and generator field current, causing power losses. The resulting power losses affect the efficiency of the PLTU generator. To determine the generator’s efficiency due to load changes, this study was carried out using manual calculation method by collecting data on specifications, resistance, and dialy log sheets of the 2x3 MW Malinau PLTU generator unit 2 conducted at PT. Nusa Daya Unit PLTU Malinau. Based on the callculation data on May 17, the highest efficiency was 79,69% at a load 2,372 MW, while the lowest efficiency was 78,03% at a load of 2,137 MW. For the callculation results of May 18, the highets efficiency was 79,51% at a load 2,342 MW, while the lowest efficiency was 76,37% at a load of 1,941 MW. The greater the power generated by generator, the higher the efficiency of the generator and the better the generator performance. Keywords: PLTU, generator, load changes, power losses, efficiency

Authors

Publication Details

Journal
Journal of Emerging Supply Chain Clean Energy and Process Engineering
Published
2024-12-13
DOI
https://doi.org/10.57102/jescee.v3i2.88
Primary Topic
Management and Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of The Effect of Load Changes on The Performance of Synchronous Generator Unit 2 at PT. PLN Nusa Daya Unit PLTU Malinau

Muhammad Arif, Ismit Mado, Andri Andri, Ferry K. Maring
Journal of Emerging Supply Chain Clean Energy and Process Engineering
Management and Optimization Techniques
article

Analysis of The Effect of Load Changes on The Performance of Synchronous Generator Unit 2 at PT. PLN Nusa Daya Unit PLTU Malinau

Muhammad Arif, Ismit Mado, Andri Andri, Ferry K. Maring
article en

Abstract

Changes in generator power losses are adjusted to the load needs in the field, which is constantly changing and can affect the value of the per- phase current and generator field current, causing power losses. The resulting power losses affect the efficiency of the PLTU generator. To determine the generator’s efficiency due to load changes, this study was carried out using manual calculation method by collecting data on specifications, resistance, and dialy log sheets of the 2x3 MW Malinau PLTU generator unit 2 conducted at PT. Nusa Daya Unit PLTU Malinau. Based on the callculation data on May 17, the highest efficiency was 79,69% at a load 2,372 MW, while the lowest efficiency was 78,03% at a load of 2,137 MW. For the callculation results of May 18, the highets efficiency was 79,51% at a load 2,342 MW, while the lowest efficiency was 76,37% at a load of 1,941 MW. The greater the power generated by generator, the higher the efficiency of the generator and the better the generator performance. Keywords: PLTU, generator, load changes, power losses, efficiency

Journal of Emerging Supply Chain Clean Energy and Process EngineeringVol. 3(2)
Openalex Percentile: Top 50%
Management and Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.