GNP/FE electrode for real time EMG signal acquisition

The goal of work is to design cost-effective electromyography (EMG) signal acquisition system using GNP/FE electrode. EMG signal represent the muscle action potentials to identify the functionality of muscle. The real time EMG signals are acquired by Ag/AgCl and GNP/FE3O4@PVDF Surface Electrodes. The EMG system has myoware sensor along with Arduino UNO. GNP/FE3O4@PVDF Electrodes with three different concentrations (1.5:1.5, 2:1, 3:0) are designed to acquire EMG signal with different age groups. The signals acquired for different age group to study functionality of the muscle. EMG signal is Pre-processed by using wavelet transform. Performance of acquired EMG signal is measured with parameters like error percentage, correlation co-efficient, signal to noise ratio (SNR). The designed GNP/FE3O4@PVDF with 3:0 ratio shows good performance to acquire EMG for all age groups with minimal error and nominal SNR.

Authors

Institutions

Publication Details

Journal
Discover Electronics
Published
2025-04-23
DOI
https://doi.org/10.1007/s44291-025-00059-w
Citations
1
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

GNP/FE electrode for real time EMG signal acquisition

V. Asha, Anitha S Prasad, M N Jayaram
1 citations
Discover Electronics
Muscle activation and electromyography studies
0.67
article

GNP/FE electrode for real time EMG signal acquisition

V. Asha, Anitha S Prasad, M N Jayaram
article en
1 citations

Abstract

The goal of work is to design cost-effective electromyography (EMG) signal acquisition system using GNP/FE electrode. EMG signal represent the muscle action potentials to identify the functionality of muscle. The real time EMG signals are acquired by Ag/AgCl and GNP/FE3O4@PVDF Surface Electrodes. The EMG system has myoware sensor along with Arduino UNO. GNP/FE3O4@PVDF Electrodes with three different concentrations (1.5:1.5, 2:1, 3:0) are designed to acquire EMG signal with different age groups. The signals acquired for different age group to study functionality of the muscle. EMG signal is Pre-processed by using wavelet transform. Performance of acquired EMG signal is measured with parameters like error percentage, correlation co-efficient, signal to noise ratio (SNR). The designed GNP/FE3O4@PVDF with 3:0 ratio shows good performance to acquire EMG for all age groups with minimal error and nominal SNR.

Discover ElectronicsVol. 2(1)
JSS Science and Technology University (IN)
Openalex Percentile: Top 33%
Muscle activation and electromyography studies
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

GNP/FE electrode for real time EMG signal acquisition — V. Asha, Anitha S Prasad, et al. · Discover Electronics (2025) | TGRS Research Map | TGRS