Analysis of Airflow, Thermal Comfort and Energy Efficiency in an Air-Conditioned Sports and Recreation Indoor Stadium

The thermal dynamics of an air-conditioned indoor stadium are challenging due to internal heat sources and heat gain from the building. An effective air conditioning system is essential for maintaining a comfortable environment. This project investigates occupant comfort and energy efficiency in a sports and recreation stadium in Sarawak, Malaysia. SolidWorks Flow Simulation 2022 and Carrier Hourly Analysis Program v5.11 were used to analyse temperature, airflow, and energy consumption. The stadium can accommodate a maximum capacity of 5,000 occupants. Six simulations were conducted to analyze thermal comfort at different supply air temperatures, using predicted mean vote and percentage of dissatisfied persons. The findings indicate that the selected water-cooled packaged unit achieves a sense of thermal neutrality at a supply air temperature of 19 °C. Meanwhile, the influence of fresh air intake on cooling load and energy consumption was examined. With a 10% fresh air intake, the cooling load is 340.4 tons, or 28.01% of the total energy cost. Increasing the intake to 31% raises the load to 453.2 tons, or 31.30% of the energy cost. At 100% fresh air intake, the cooling load reaches 822.7 tons, accounting for 40.69% of total energy costs. After careful evaluation, a 31% fresh air intake aligns with ASHRAE guidelines, ensuring a balance between ventilation standards and practical airflow at 40,440 CFM. These findings help stakeholders implement efficient air conditioning solutions that enhance occupant comfort and energy efficiency, supporting climate action initiatives.

Authors

Institutions

Publication Details

Journal
Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
Published
2025-04-20
DOI
https://doi.org/10.37934/arfmts.130.1.7790
Primary Topic
Evacuation and Crowd Dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Airflow, Thermal Comfort and Energy Efficiency in an Air-Conditioned Sports and Recreation Indoor Stadium

Henry Shu-Hung Chung, H.V. Kok, Li Jerry Sung Teck, Lee Yeu Yee et al.
Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
Evacuation and Crowd Dynamics
article

Analysis of Airflow, Thermal Comfort and Energy Efficiency in an Air-Conditioned Sports and Recreation Indoor Stadium

Henry Shu-Hung Chung, H.V. Kok, Li Jerry Sung Teck, Lee Yeu Yee, Voon Charlie Sia Chin
article en

Abstract

The thermal dynamics of an air-conditioned indoor stadium are challenging due to internal heat sources and heat gain from the building. An effective air conditioning system is essential for maintaining a comfortable environment. This project investigates occupant comfort and energy efficiency in a sports and recreation stadium in Sarawak, Malaysia. SolidWorks Flow Simulation 2022 and Carrier Hourly Analysis Program v5.11 were used to analyse temperature, airflow, and energy consumption. The stadium can accommodate a maximum capacity of 5,000 occupants. Six simulations were conducted to analyze thermal comfort at different supply air temperatures, using predicted mean vote and percentage of dissatisfied persons. The findings indicate that the selected water-cooled packaged unit achieves a sense of thermal neutrality at a supply air temperature of 19 °C. Meanwhile, the influence of fresh air intake on cooling load and energy consumption was examined. With a 10% fresh air intake, the cooling load is 340.4 tons, or 28.01% of the total energy cost. Increasing the intake to 31% raises the load to 453.2 tons, or 31.30% of the energy cost. At 100% fresh air intake, the cooling load reaches 822.7 tons, accounting for 40.69% of total energy costs. After careful evaluation, a 31% fresh air intake aligns with ASHRAE guidelines, ensuring a balance between ventilation standards and practical airflow at 40,440 CFM. These findings help stakeholders implement efficient air conditioning solutions that enhance occupant comfort and energy efficiency, supporting climate action initiatives.

Journal of Advanced Research in Fluid Mechanics and Thermal SciencesVol. 130(1)
Forest Department Sarawak (MY), Swinburne University of Technology Sarawak Campus (MY)
Openalex Percentile: Top 89%
Evacuation and Crowd Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.