Passive Design of Natural Ventilation System for Thermal Comfort in Saminah Sihyadi Mosque, Surakarta, Indonesia

The design of the mosque building influences the level of comfort for the congregation in worship, including thermal comfort. Located in a dense area, the Saminah Sihyadi Mosque applies a passive design to provide thermal comforts, such as a vast opening system. This article aims to study the condition of natural ventilation in the Saminah Sihyadi Mosque and the opening system applied according to Indonesian standards. The research measured the temperature, humidity, and wind velocity using an Environment Meter. Measurements were conducted five times, following the order of the prayer times over two days with different types of opening. The measurement results are compared with Indonesian National Standards (Standar Nasional Indonesia or SNI) to determine the suitability of the comfort level. The Saminah Sihyadi Mosque has sufficient openings according to standards. The measurement results show that the passive design can reduce the temperature and humidity inside the mosque compared to conditions outside the mosque. The wind moved at a speed that meets thermal comfort standards, ensuring that the implemented passive design successfully regulates thermal comfort.

Authors

Institutions

Publication Details

Journal
Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
Published
2025-04-20
DOI
https://doi.org/10.37934/arfmts.130.1.5163
Primary Topic
Architectural and Urban Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Passive Design of Natural Ventilation System for Thermal Comfort in Saminah Sihyadi Mosque, Surakarta, Indonesia

Mahatma Sindu Suryo, Silfia Mona Aryani, Wisnu Aji Prabowo
Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
Architectural and Urban Studies
article

Passive Design of Natural Ventilation System for Thermal Comfort in Saminah Sihyadi Mosque, Surakarta, Indonesia

Mahatma Sindu Suryo, Silfia Mona Aryani, Wisnu Aji Prabowo
article en

Abstract

The design of the mosque building influences the level of comfort for the congregation in worship, including thermal comfort. Located in a dense area, the Saminah Sihyadi Mosque applies a passive design to provide thermal comforts, such as a vast opening system. This article aims to study the condition of natural ventilation in the Saminah Sihyadi Mosque and the opening system applied according to Indonesian standards. The research measured the temperature, humidity, and wind velocity using an Environment Meter. Measurements were conducted five times, following the order of the prayer times over two days with different types of opening. The measurement results are compared with Indonesian National Standards (Standar Nasional Indonesia or SNI) to determine the suitability of the comfort level. The Saminah Sihyadi Mosque has sufficient openings according to standards. The measurement results show that the passive design can reduce the temperature and humidity inside the mosque compared to conditions outside the mosque. The wind moved at a speed that meets thermal comfort standards, ensuring that the implemented passive design successfully regulates thermal comfort.

Journal of Advanced Research in Fluid Mechanics and Thermal SciencesVol. 130(1)
Sebelas Maret University (ID), Tokyo Metropolitan University (JP)
Universitas Sebelas Maret
Openalex Percentile: Top 91%
Architectural and Urban Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.