Sliding Rail Technique (Mandelli's), a Better Method to Repair Thoracoabdominal Aortic Aneurysms Controlled Release Fenestrated Endoprosthesis
Fenestrated endovascular aortic aneurysm repair is a minimally invasive technique used for the treatment of thoracoabdominal aortic aneurysms (TAAAs). We report an easy method for positioning the controlled-release fenestrated endoprosthesis, associated with a less invasive approach for positioning the endoprosthesis and catheterization of the target vessels through percutaneous access.
Authors
- Felipe Farias Pereira da Câmara Barros (ORCID: https://orcid.org/0000-0003-2071-6930)
- Nilo César Barbosa Mandelli (ORCID: https://orcid.org/0000-0001-7444-4294)
- Fernando Tavares Brasil Teixeira
- Laura Vicentini Correa Brunstein
Institutions
- Universidade Federal do Rio de Janeiro (BR)
- Fundação Universitária de Cardiologia (BR)
- Hospital Universitário Clementino Fraga Filho (BR)
- Universidade Luterana do Brasil (BR)
Publication Details
- Journal
- Aorta
- Published
- 2024-10-01
- DOI
- https://doi.org/10.1055/a-2541-8455
- Citations
- 1
- Primary Topic
- Aortic aneurysm repair treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.42