Carbon Dots-Based Surface Plasmon Resonance Manganese Ion Fiber Sensor for Multi-Use Scenarios

Abstract Heavy metal ions have drawn enough attention due to their harm to both humans and environments, and there has been an urgent need for stable and quick detection of them. Besides, the manganese ion is one of the most abundant ions in urban water systems, which needs to be monitored carefully. Hereby, a carbon dots (CDs) (the microwave method) based surface plasmon resonance (SPR) Mn 2+ sensor has been proposed and discussed, which could achieve high detection sensitivity of 6.383 nm/lg(ppb) in the range of 0 ppb–200 ppb on manganese ions, with the detection limit of 0.3462 ppb. The proposed sensor also possesses high stability upon time and temperature, and it also has great ion selectivity against 9 other ions. Practical usage scenarios have been tested on the human serum, tap water, lake water, and river water, which confirm that the proposed sensor holds great potential for both blood tests and environmental monitoring.

Authors

Institutions

Publication Details

Journal
Photonic Sensors
Published
2025-04-21
DOI
https://doi.org/10.1007/s13320-025-0708-x
Citations
3
Primary Topic
Carbon and Quantum Dots Applications
Type
article
Field-Weighted Citation Impact
1.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Carbon Dots-Based Surface Plasmon Resonance Manganese Ion Fiber Sensor for Multi-Use Scenarios

Xin Yan, Tonglei Cheng, Haihui Li, Rao Fu et al.
3 citations
Photonic Sensors
Carbon and Quantum Dots Applications
1.55
article

Carbon Dots-Based Surface Plasmon Resonance Manganese Ion Fiber Sensor for Multi-Use Scenarios

Xin Yan, Tonglei Cheng, Haihui Li, Rao Fu, Taotao Hu
article en
3 citations

Abstract

Abstract Heavy metal ions have drawn enough attention due to their harm to both humans and environments, and there has been an urgent need for stable and quick detection of them. Besides, the manganese ion is one of the most abundant ions in urban water systems, which needs to be monitored carefully. Hereby, a carbon dots (CDs) (the microwave method) based surface plasmon resonance (SPR) Mn 2+ sensor has been proposed and discussed, which could achieve high detection sensitivity of 6.383 nm/lg(ppb) in the range of 0 ppb–200 ppb on manganese ions, with the detection limit of 0.3462 ppb. The proposed sensor also possesses high stability upon time and temperature, and it also has great ion selectivity against 9 other ions. Practical usage scenarios have been tested on the human serum, tap water, lake water, and river water, which confirm that the proposed sensor holds great potential for both blood tests and environmental monitoring.

Photonic SensorsVol. 15(3)
State Key Laboratory of Synthetical Automation for Process Industries, Northeastern University (CN)
Openalex Percentile: Top 18%
Carbon and Quantum Dots Applications
1.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.