Clinical Impact of the Incision of the Capsule Floor During Generator Replacement on Cardiac Implantable Electronic Device Infection Risk: A Single‐Center Experience
Generator replacement without incision of the capsule floor during generator replacement was associated with increased CIED infection risk. To minimize CIED infection risk, capsule floor incision could be considered during generator replacement.
Authors
- Burak Açar (ORCID: https://orcid.org/0000-0003-3217-5000)
- Özlem Güler (ORCID: https://orcid.org/0000-0002-1444-7730)
- Kaan Hanci (ORCID: https://orcid.org/0000-0003-4843-7415)
- Hacer Dogan (ORCID: https://orcid.org/0000-0002-4871-4999)
- Umut Çelikyurt (ORCID: https://orcid.org/0000-0003-4957-7102)
- İpek Komşuoğlu Çelikyurt (ORCID: https://orcid.org/0000-0003-0895-3490)
- Ayşen Ağaçdiken
- Ahmet Vural
Institutions
- Kocaeli Üniversitesi (TR)
Publication Details
- Journal
- Journal of Cardiovascular Electrophysiology
- Published
- 2025-04-21
- DOI
- https://doi.org/10.1111/jce.16695
- Citations
- 2
- Primary Topic
- Cardiac pacing and defibrillation studies
- Type
- article
- Field-Weighted Citation Impact
- 2.78