Separation and Detection of Charged Unilamellar Vesicles in Vacuum by a Frequency-Controlled Quadrupole Mass Sensor

Extracellular vesicles (EVs) are membranous particles released by cells and are considered to be promising sources of biomarkers for various diseases. Mass spectrometry (MS) analysis of EVs requires a sample of purified and detergent-lysed EVs. Purification of EVs is laborious, based on size, density, or surface nature, and requires large amounts of the source material (e.g., blood, spinal fluid). We have employed synthetically produced large unilamellar lipid vesicles (LUVs) as analogs of EVs to demonstrate an alternative approach to vesicle separation for subsequent mass spectrometry analysis of their composition. Mass-to-charge ratio <i>m</i>/<i>z</i> separation by frequency-controlled quadrupole was employed to filter narrow-size distributions of LUVs from a water sample. Lipid vesicles were positively charged with nanoelectrospray and transferred into a vacuum using two wide <i>m</i>/<i>z</i>-range frequency-controlled quadrupoles. The <i>m</i>/<i>z</i>, charges, and masses of individual vesicles were obtained by the nondestructive single-pass charge detector. The resolving mode of the second quadrupole with <i>m</i>/<i>z</i> RSD < 10% allowed to separate size selected distributions of vesicles with modal diameters of 88, 112, 130, 162, and 190 nm at corresponding quadrupole <i>m</i>/<i>z</i> settings of 2.5 × 10<sup>5</sup>, 5 × 10<sup>5</sup>, 8 × 10<sup>5</sup>, 1.5 × 10<sup>6</sup>, and 2.5 × 10<sup>6</sup>, respectively with a rate of 20-100 counts per minute. The distributions of bioparticles with masses between 10<sup>8</sup> and 10<sup>10</sup> Da were separated from human blood serum in the pilot experiment. The presented approach for lipid vesicle separation encourages the development of new techniques for the direct mass-spectrometric analysis of biomarkers in MS-separated EVs in a vacuum.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-04-22
DOI
https://doi.org/10.1021/acs.analchem.4c05730
Primary Topic
Nanopore and Nanochannel Transport Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Separation and Detection of Charged Unilamellar Vesicles in Vacuum by a Frequency-Controlled Quadrupole Mass Sensor

Bernd Abel, Anatolii Spesyvyi, Marek Cebecauer, Agnieszka Olżyńska et al.
Analytical Chemistry
Nanopore and Nanochannel Transport Studies
article

Separation and Detection of Charged Unilamellar Vesicles in Vacuum by a Frequency-Controlled Quadrupole Mass Sensor

Bernd Abel, Anatolii Spesyvyi, Marek Cebecauer, Agnieszka Olżyńska, Aleš Charvát, Michaela Malečková, Miroslav Polášek, Ján Žabka, Zuzana Johanovská
article en

Abstract

Extracellular vesicles (EVs) are membranous particles released by cells and are considered to be promising sources of biomarkers for various diseases. Mass spectrometry (MS) analysis of EVs requires a sample of purified and detergent-lysed EVs. Purification of EVs is laborious, based on size, density, or surface nature, and requires large amounts of the source material (e.g., blood, spinal fluid). We have employed synthetically produced large unilamellar lipid vesicles (LUVs) as analogs of EVs to demonstrate an alternative approach to vesicle separation for subsequent mass spectrometry analysis of their composition. Mass-to-charge ratio <i>m</i>/<i>z</i> separation by frequency-controlled quadrupole was employed to filter narrow-size distributions of LUVs from a water sample. Lipid vesicles were positively charged with nanoelectrospray and transferred into a vacuum using two wide <i>m</i>/<i>z</i>-range frequency-controlled quadrupoles. The <i>m</i>/<i>z</i>, charges, and masses of individual vesicles were obtained by the nondestructive single-pass charge detector. The resolving mode of the second quadrupole with <i>m</i>/<i>z</i> RSD < 10% allowed to separate size selected distributions of vesicles with modal diameters of 88, 112, 130, 162, and 190 nm at corresponding quadrupole <i>m</i>/<i>z</i> settings of 2.5 × 10<sup>5</sup>, 5 × 10<sup>5</sup>, 8 × 10<sup>5</sup>, 1.5 × 10<sup>6</sup>, and 2.5 × 10<sup>6</sup>, respectively with a rate of 20-100 counts per minute. The distributions of bioparticles with masses between 10<sup>8</sup> and 10<sup>10</sup> Da were separated from human blood serum in the pilot experiment. The presented approach for lipid vesicle separation encourages the development of new techniques for the direct mass-spectrometric analysis of biomarkers in MS-separated EVs in a vacuum.

Analytical ChemistryVol. 97(17)
Institute of Chemical Technology (IN), Charles University (CZ), Czech Academy of Sciences, J. Heyrovský Institute of Physical Chemistry (CZ), Leibniz Institute of Surface Engineering (DE), Leipzig University (DE)
Deutsche Forschungsgemeinschaft, Grantová Agentura České Republiky, HORIZON EUROPE Widening participation and spreading excellence
Affordable and clean energy
Openalex Percentile: Top 92%
Nanopore and Nanochannel Transport Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.