Development of a Tissue Oxygen Saturation Imaging Technique Based on Electronic Endoscopy

Hypoxemia, a common clinical phenomenon, is closely associated with various pathological conditions, including tumors and inflammatory diseases. The detection of tissue hypoxia holds significant potential for the detailed diagnosis of these conditions. Existing endoscopes, with the aid of probes, can perform point measurements of tissue oxygen saturation (<i>S</i><i>t</i><i>O</i><sub>2</sub>), a well-established method for assessment. However, this approach has limitations, including a small measurement range and slow measurement speed, which restrict its further application. In addition, hyperspectral imaging featured with a large number of spectral bands is used in conventional strategies, which increases the complexity of the endoscope. This work aims to develop an endoscopic technique for measuring <i>S</i><i>t</i><i>O</i><sub>2</sub> in digestive tract tissue, ensuring compatibility with existing imaging systems, using fewer spectral bands, and without requiring significant modifications to current surgical and diagnostic endoscopic systems. The Monte Carlo method is used to numerically model light transport and its interaction with human tissues, establishing the relationship between tissue reflectance spectra and tissue properties. Based on this, a lookup-table-based (LUT) model has been developed to enable hardware acceleration for <i>S</i><i>t</i><i>O</i><sub>2</sub> measurement. Three illumination wavelength bands from commercially available LEDs were selected to analyze <i>S</i><i>t</i><i>O</i><sub>2</sub> from tissue reflectance spectra. The effectiveness and accuracy of this method were validated using a prototype device, with experiments conducted on tissue-simulating phantoms. The experimental results are in good agreement with the measurements from a visible light spectrophotometer, with the MAE of tissue oxygen values no more than 4.4%. These findings confirm the effectiveness of this technology in assessing <i>S</i><i>t</i><i>O</i><sub>2</sub> in digestive tract tissue and demonstrate its high potential for real-time blood oxygen measurement with a simple system and low-cost characteristics.

Authors

Publication Details

Journal
Applied Optics
Published
2025-04-22
DOI
https://doi.org/10.1364/ao.559796
Primary Topic
Ultrasound in Clinical Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Tissue Oxygen Saturation Imaging Technique Based on Electronic Endoscopy

Jiawei Cong, Yu Liu, Xiaosong Bai, Jian Wen et al.
Applied Optics
Ultrasound in Clinical Applications
article

Development of a Tissue Oxygen Saturation Imaging Technique Based on Electronic Endoscopy

Jiawei Cong, Yu Liu, Xiaosong Bai, Jian Wen, Zhiqiang Zhou
article en

Abstract

Hypoxemia, a common clinical phenomenon, is closely associated with various pathological conditions, including tumors and inflammatory diseases. The detection of tissue hypoxia holds significant potential for the detailed diagnosis of these conditions. Existing endoscopes, with the aid of probes, can perform point measurements of tissue oxygen saturation (<i>S</i><i>t</i><i>O</i><sub>2</sub>), a well-established method for assessment. However, this approach has limitations, including a small measurement range and slow measurement speed, which restrict its further application. In addition, hyperspectral imaging featured with a large number of spectral bands is used in conventional strategies, which increases the complexity of the endoscope. This work aims to develop an endoscopic technique for measuring <i>S</i><i>t</i><i>O</i><sub>2</sub> in digestive tract tissue, ensuring compatibility with existing imaging systems, using fewer spectral bands, and without requiring significant modifications to current surgical and diagnostic endoscopic systems. The Monte Carlo method is used to numerically model light transport and its interaction with human tissues, establishing the relationship between tissue reflectance spectra and tissue properties. Based on this, a lookup-table-based (LUT) model has been developed to enable hardware acceleration for <i>S</i><i>t</i><i>O</i><sub>2</sub> measurement. Three illumination wavelength bands from commercially available LEDs were selected to analyze <i>S</i><i>t</i><i>O</i><sub>2</sub> from tissue reflectance spectra. The effectiveness and accuracy of this method were validated using a prototype device, with experiments conducted on tissue-simulating phantoms. The experimental results are in good agreement with the measurements from a visible light spectrophotometer, with the MAE of tissue oxygen values no more than 4.4%. These findings confirm the effectiveness of this technology in assessing <i>S</i><i>t</i><i>O</i><sub>2</sub> in digestive tract tissue and demonstrate its high potential for real-time blood oxygen measurement with a simple system and low-cost characteristics.

Applied OpticsVol. 64(15)
Openalex Percentile: Top 90%
Ultrasound in Clinical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.