Evaluation of a near infrared spectroscopy based method for the estimation of substance P in saliva of patients with COPD

Identifying noninvasive specific disease biomarkers that can provide valuable information about chronic obstructive pulmonary disease (COPD) progression, potential complications, or treatment response is of paramount importance. In this study, we propose the validation of an innovative near-infrared (NIR) device that utilizes near-infrared light reflectance techniques combined with data validation through a convolutional neural network for the detection of substance P in non-invasive saliva samples. We conducted an analytical observational cross-sectional study at a leading university hospital between January and March 2022, including patients with COPD and controls without the disease. Following the collection of clinical data, a saliva sample was obtained for the determination of substance P which was analyzed both by the NIR device and an Enzyme-Linked Immunosorbent Assay. Direct comparisons were made, and Bland-Altman plots were constructed to assess the level of agreement between the two measurements. The sample consisted of 102 subjects, 44 with COPD and 58 controls. The average differences between the two measurement methods yielded similar results with no significant differences between them, showing a value of 110.2 (16.1) pg/ml for the NIR device and 110.5 (16.7) pg/ml for the ELISA determination (p > 0.05). The Bland-Altman plots show a small difference and a level of agreement consistent with good measurement by the NIR device. The results of this study validate the efficacy of a NIR device combined with a convolutional neural network for detecting substance P in the saliva of COPD patients.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-04-22
DOI
https://doi.org/10.1038/s41598-025-98522-x
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of a near infrared spectroscopy based method for the estimation of substance P in saliva of patients with COPD

Remedios Otero, C Zarrias Caballero, José Luís López-Campos, Belén Muñoz-Sánchez et al.
Scientific Reports
Hemodynamic Monitoring and Therapy
article

Evaluation of a near infrared spectroscopy based method for the estimation of substance P in saliva of patients with COPD

Remedios Otero, C Zarrias Caballero, José Luís López-Campos, Belén Muñoz-Sánchez, Carmen Marín-Hinojosa, Esther Quintana‐Gallego, Rocío Reinoso‐Arija, Jose A Jiménez-Ruiz, Alba Fernández-Boza, Carlos Carrera-Cueva
article en

Abstract

Identifying noninvasive specific disease biomarkers that can provide valuable information about chronic obstructive pulmonary disease (COPD) progression, potential complications, or treatment response is of paramount importance. In this study, we propose the validation of an innovative near-infrared (NIR) device that utilizes near-infrared light reflectance techniques combined with data validation through a convolutional neural network for the detection of substance P in non-invasive saliva samples. We conducted an analytical observational cross-sectional study at a leading university hospital between January and March 2022, including patients with COPD and controls without the disease. Following the collection of clinical data, a saliva sample was obtained for the determination of substance P which was analyzed both by the NIR device and an Enzyme-Linked Immunosorbent Assay. Direct comparisons were made, and Bland-Altman plots were constructed to assess the level of agreement between the two measurements. The sample consisted of 102 subjects, 44 with COPD and 58 controls. The average differences between the two measurement methods yielded similar results with no significant differences between them, showing a value of 110.2 (16.1) pg/ml for the NIR device and 110.5 (16.7) pg/ml for the ELISA determination (p > 0.05). The Bland-Altman plots show a small difference and a level of agreement consistent with good measurement by the NIR device. The results of this study validate the efficacy of a NIR device combined with a convolutional neural network for detecting substance P in the saliva of COPD patients.

Scientific ReportsVol. 15(1)
Instituto de Salud Carlos III (ES), Centro de Investigación Biomédica en Red de Enfermedades Respiratorias (ES), Instituto de Biomedicina de Sevilla (ES), Hospital Universitario Virgen del Rocío (ES), Universidad de Sevilla (ES)
Ministerio de Ciencia e Innovación, Instituto de Salud Carlos III
Zero hunger
Openalex Percentile: Top 86%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.