Model Design and Study of a U-Channel Photonic Crystal Fib Optic Sensor for Measuring Glucose Concentration in Blood

This research introduces a biosensor utilizing surface plasmon resonance in a photonic crystal fiber (PCF) configuration. PCF uses fused silica as the base material, with a layer of gold placed over the U-channels in the cross-section of the fiber to create a surface plasmon resonance. There are three different sizes of internal fiber optic air hole diameters, with a larger channel circle below the u-channel for the formation of an energy leakage window. COMSOL software 6.0 assisted us in tuning the fiber optic structure and performance for the study, and the structural parameters analyzed mainly include the channel circle diameter, the channel circle spacing, the profundity measurement of the polished layer, and the nanoscale size variation of metal films. The results of the simulation study show that the optical fiber sensor achieves refractive index (RI) responsiveness across the 1.30 to 1.41 range, and in the RI interval of 1.40 to 1.41, the sensor exhibits the largest resonance peak shift, and its highest sensitivity reaches 10,200 nm/RIU, and the smallest full width at half peak (FWHM) corresponds to the RI of 1.34 with a value of 4.8 nm, and the highest figure of merit (FOM) corresponds to the RI of 1.34 with a value of 895.83 (1/RIU). COMSOL 6.0 simulation software, was used to simulate the changes in blood refractive index corresponding to different glucose concentrations, and the detection performance of the sensor for different concentrations of glucose was tested. Then, the results show that the glucose concentration in 75 mg/dL-175 mg/dL with RI detection sensitivity is 3750 nm/RIU, where the maximum refractive index sensitivity is 5455 nm/RIU. It shows that the sensor can be applied in the field of biomedical applications, with its convenience, fast response, and high sensitivity, it has great potential and development prospect in the market.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-04-22
DOI
https://doi.org/10.3390/s25092647
Citations
5
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
3.65

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Model Design and Study of a U-Channel Photonic Crystal Fib Optic Sensor for Measuring Glucose Concentration in Blood

Qianju Song, Lei Zhao, Zao Yi, Yougen Yi et al.
5 citations
Sensors
Advanced Fiber Optic Sensors
3.65
article

Model Design and Study of a U-Channel Photonic Crystal Fib Optic Sensor for Measuring Glucose Concentration in Blood

Qianju Song, Lei Zhao, Zao Yi, Yougen Yi, Tangyou Sun
article en
5 citations

Abstract

This research introduces a biosensor utilizing surface plasmon resonance in a photonic crystal fiber (PCF) configuration. PCF uses fused silica as the base material, with a layer of gold placed over the U-channels in the cross-section of the fiber to create a surface plasmon resonance. There are three different sizes of internal fiber optic air hole diameters, with a larger channel circle below the u-channel for the formation of an energy leakage window. COMSOL software 6.0 assisted us in tuning the fiber optic structure and performance for the study, and the structural parameters analyzed mainly include the channel circle diameter, the channel circle spacing, the profundity measurement of the polished layer, and the nanoscale size variation of metal films. The results of the simulation study show that the optical fiber sensor achieves refractive index (RI) responsiveness across the 1.30 to 1.41 range, and in the RI interval of 1.40 to 1.41, the sensor exhibits the largest resonance peak shift, and its highest sensitivity reaches 10,200 nm/RIU, and the smallest full width at half peak (FWHM) corresponds to the RI of 1.34 with a value of 4.8 nm, and the highest figure of merit (FOM) corresponds to the RI of 1.34 with a value of 895.83 (1/RIU). COMSOL 6.0 simulation software, was used to simulate the changes in blood refractive index corresponding to different glucose concentrations, and the detection performance of the sensor for different concentrations of glucose was tested. Then, the results show that the glucose concentration in 75 mg/dL-175 mg/dL with RI detection sensitivity is 3750 nm/RIU, where the maximum refractive index sensitivity is 5455 nm/RIU. It shows that the sensor can be applied in the field of biomedical applications, with its convenience, fast response, and high sensitivity, it has great potential and development prospect in the market.

SensorsVol. 25(9)
Southwest University of Science and Technology (CN), Central South University (CN), Jishou University (CN), Lanzhou University of Technology (CN), Joint Laboratory for Extreme Conditions Matter Properties (CN), Guilin University of Electronic Technology (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 7%
Advanced Fiber Optic Sensors
3.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.