Evaluation of the Differences between Axial and Double Oblique Measurements of the Ascending Aorta on Gated, Contrast-Enhanced Thoracic Computed Tomography Scans: A Technical Note

The purpose of the study was to compare axial measurements of the ascending thoracic aorta on gated CT study studies with double oblique measurements and calculate the divergence between orthogonal axial and double oblique diameters of the tubular ascending aorta.Retrospective measurements of axial and double oblique diameters were obtained in 153 consecutive patients.On average, the axial dimension exceeded the double oblique measurement.Our study endorsed the subtraction of 0.58 mm from the axial diameter in order to obtain the double oblique measurement.

Authors

Institutions

Publication Details

Journal
Aorta
Published
2024-10-01
DOI
https://doi.org/10.1055/a-2537-5390
Citations
1
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the Differences between Axial and Double Oblique Measurements of the Ascending Aorta on Gated, Contrast-Enhanced Thoracic Computed Tomography Scans: A Technical Note

Paul Stark, Eric Chang
1 citations
Aorta
Aortic Disease and Treatment Approaches
0.42
article

Evaluation of the Differences between Axial and Double Oblique Measurements of the Ascending Aorta on Gated, Contrast-Enhanced Thoracic Computed Tomography Scans: A Technical Note

Paul Stark, Eric Chang
article en
1 citations

Abstract

The purpose of the study was to compare axial measurements of the ascending thoracic aorta on gated CT study studies with double oblique measurements and calculate the divergence between orthogonal axial and double oblique diameters of the tubular ascending aorta.Retrospective measurements of axial and double oblique diameters were obtained in 153 consecutive patients.On average, the axial dimension exceeded the double oblique measurement.Our study endorsed the subtraction of 0.58 mm from the axial diameter in order to obtain the double oblique measurement.

AortaVol. 12(05)
University of California San Diego (US), VA San Diego Healthcare System (US)
Openalex Percentile: Top 29%
Aortic Disease and Treatment Approaches
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.