Modeling, Validation, and Application of Instrument Response Function in the Form of Mixed Poisson Distribution for Single-Particle ICP-MS

Single-particle inductively coupled plasma mass spectrometry (spICP-MS) is a sensitive and convenient technique for characterizing nanoparticles in suspension, enabling the determination of particle size, particle size distribution (PSD) and particle number concentration (PNC) from time-resolved signals of particle events. Accurate acquisition and modeling of event intensity distributions (EIDs) are critical steps in expanding functionality and improving measurement accuracy. In this work, we explored the broadening factors of EID, establishing and validating a robust instrument response function (IRF) in the form of a mixed Poisson distribution that reliably correlates PSD with EID across varying operating conditions. The EID tailing caused by particle coincidence is quantified and eliminated through Monte Carlo simulations grounded in the homogeneous Poisson process, and then the recovered EID is deconvoluted by IRF to yield high-fidelity PSD, improving the accuracy of PSD and PNC obtained by spICP-MS. For monodisperse gold nanoparticles (AuNPs) and AuNP mixtures, stable PSDs can be recovered from the broadened EIDs by IRF deconvolution, yielding results closely aligned with those obtained by transmission electron microscopy, thus increasing the size resolution to about 7 nm in both simulated and actual samples. The application of IRF to the measurement of nanoparticle agglomerates was also demonstrated, and the probability mass function of agglomeration numbers was successfully resolved. This technique is expected to leverage the high-throughput advantages of spICP-MS in the quantification of nanoparticle mixtures or agglomerates.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-04-22
DOI
https://doi.org/10.1021/acs.analchem.5c00089
Citations
1
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.75

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modeling, Validation, and Application of Instrument Response Function in the Form of Mixed Poisson Distribution for Single-Particle ICP-MS

Maoguo Luo, Guanglu Ge, Xiaochun Wu, Yinglu Ji et al.
1 citations
Analytical Chemistry
Analytical chemistry methods development
0.75
article

Modeling, Validation, and Application of Instrument Response Function in the Form of Mixed Poisson Distribution for Single-Particle ICP-MS

Maoguo Luo, Guanglu Ge, Xiaochun Wu, Yinglu Ji, Renxiao Liu, Chunhui Wang, Yang Xiao-feng, Dexing Li, Hongwu Li
article en
1 citations

Abstract

Single-particle inductively coupled plasma mass spectrometry (spICP-MS) is a sensitive and convenient technique for characterizing nanoparticles in suspension, enabling the determination of particle size, particle size distribution (PSD) and particle number concentration (PNC) from time-resolved signals of particle events. Accurate acquisition and modeling of event intensity distributions (EIDs) are critical steps in expanding functionality and improving measurement accuracy. In this work, we explored the broadening factors of EID, establishing and validating a robust instrument response function (IRF) in the form of a mixed Poisson distribution that reliably correlates PSD with EID across varying operating conditions. The EID tailing caused by particle coincidence is quantified and eliminated through Monte Carlo simulations grounded in the homogeneous Poisson process, and then the recovered EID is deconvoluted by IRF to yield high-fidelity PSD, improving the accuracy of PSD and PNC obtained by spICP-MS. For monodisperse gold nanoparticles (AuNPs) and AuNP mixtures, stable PSDs can be recovered from the broadened EIDs by IRF deconvolution, yielding results closely aligned with those obtained by transmission electron microscopy, thus increasing the size resolution to about 7 nm in both simulated and actual samples. The application of IRF to the measurement of nanoparticle agglomerates was also demonstrated, and the probability mass function of agglomeration numbers was successfully resolved. This technique is expected to leverage the high-throughput advantages of spICP-MS in the quantification of nanoparticle mixtures or agglomerates.

Analytical ChemistryVol. 97(17)
Beijing Institute of Technology (CN), Center for NanoScience (DE), PerkinElmer (Ireland) (IE), National Center for Nanoscience and Technology (CN), University of Chinese Academy of Sciences (CN), PerkinElmer (United States) (US)
National Key Research and Development Program of China
Openalex Percentile: Top 33%
Analytical chemistry methods development
0.75
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.