Quantitative comparison of the performance of acoustic, optical and pressure sensors for pulse wave analysis

Arterial pulse wave measurement is beneficial in clinical health assessment and is important for effectively diagnosing different types of cardiovascular disease. Computational pulse signal analysis utilizes sensors and signal processing techniques to understand, classify, and predict disease pulse patterns. However, the choice of sensor types impacts the measurement results. This study presents the first comprehensive quantitative comparison of three sensor modalities (acoustic, optical, and pressure) for radial pulse measurement, employing a novel multi-parameter analysis framework that combines time-domain, frequency-domain, and PRV measures. Among various available types, three types of sensors are compared: an acoustic sensor, an optical sensor, and a pressure sensor. Pulse wave signals were recorded from the radial artery of 30 participants using these three sensors, and the performance was evaluated using various feature extraction methods like time domain, frequency domain and pulse rate variability (PRV) measures. Further, statistical analysis (ANOVA) of the PRV measures was carried out to compare the differences in the means of the various PRV measures. Time and frequency domain features varied across sensor types, but no statistical differences were found in PRV measures across sensors. Based on the experimental results, the pressure sensor was found to perform better in capturing comprehensive wrist pulse information. The research provides evidence-based guidelines for sensor selection in pulse wave analysis applications. The findings have direct applications in developing wearable cardiovascular monitoring devices, where sensor choice critically impacts device accuracy and reliability. and clinical settings requiring pulse wave analysis for cardiovascular disease diagnosis.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-04-23
DOI
https://doi.org/10.1038/s41598-025-98488-w
Citations
3
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
2.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative comparison of the performance of acoustic, optical and pressure sensors for pulse wave analysis

Amber Shrivastava, Apakrita Tayade, Saurav Kumar, B. Ravi
3 citations
Scientific Reports
Non-Invasive Vital Sign Monitoring
2.02
article

Quantitative comparison of the performance of acoustic, optical and pressure sensors for pulse wave analysis

Amber Shrivastava, Apakrita Tayade, Saurav Kumar, B. Ravi
article en
3 citations

Abstract

Arterial pulse wave measurement is beneficial in clinical health assessment and is important for effectively diagnosing different types of cardiovascular disease. Computational pulse signal analysis utilizes sensors and signal processing techniques to understand, classify, and predict disease pulse patterns. However, the choice of sensor types impacts the measurement results. This study presents the first comprehensive quantitative comparison of three sensor modalities (acoustic, optical, and pressure) for radial pulse measurement, employing a novel multi-parameter analysis framework that combines time-domain, frequency-domain, and PRV measures. Among various available types, three types of sensors are compared: an acoustic sensor, an optical sensor, and a pressure sensor. Pulse wave signals were recorded from the radial artery of 30 participants using these three sensors, and the performance was evaluated using various feature extraction methods like time domain, frequency domain and pulse rate variability (PRV) measures. Further, statistical analysis (ANOVA) of the PRV measures was carried out to compare the differences in the means of the various PRV measures. Time and frequency domain features varied across sensor types, but no statistical differences were found in PRV measures across sensors. Based on the experimental results, the pressure sensor was found to perform better in capturing comprehensive wrist pulse information. The research provides evidence-based guidelines for sensor selection in pulse wave analysis applications. The findings have direct applications in developing wearable cardiovascular monitoring devices, where sensor choice critically impacts device accuracy and reliability. and clinical settings requiring pulse wave analysis for cardiovascular disease diagnosis.

Scientific ReportsVol. 15(1)
Indian Institute of Technology Bombay (IN)
Indian Institute of Technology Bombay
Affordable and clean energy
Openalex Percentile: Top 14%
Non-Invasive Vital Sign Monitoring
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.