Enhancing Post‐Exercise Oxygen Kinetics Modeling With Physiological Bounds and Manual VO<sub>2</sub>_<sub>baseline</sub> Input: A Novel Approach

This study addresses a critical limitation in existing computational tools for modeling post-exercise oxygen consumption kinetics (V̇O<sub>2</sub>). Although exponential modeling provides practical insights into recovery dynamics, the inability to incorporate an individual's pre-exercise baseline oxygen consumption value (V̇O<sub>2</sub>_<sub>baseline</sub>) can lead to inaccurate interpretations. A user-defined baseline allows for more precise modeling by aligning recovery kinetics with the true physiological endpoint, representing the individual's actual recovery target after a sufficient rest. To overcome this limitation, this study employs a customized Python algorithm that incorporates user-defined baseline V̇O<sub>2</sub> and uses both mono-exponential and bi-exponential models, aiming to improve upon existing analytical methods. Twenty-two male amateur soccer players participated in this study and performed a 30-s Wingate test. V̇O<sub>2</sub> was measured continuously before, during, and after exercise via a metabolic gas analyzer. Both mono-exponential and bi-exponential models were used to analyze post-exercise V̇O<sub>2</sub> kinetics. The analysis was performed using Origin software (as the reference tool), GedaeLab (a specialized web-based platform), and a custom-developed Python algorithm. The bi-exponential model demonstrated superior fit compared to the mono-exponential model with higher determination coefficient (R<sup>2</sup>) values. Specifically, R<sup>2</sup> values were 0.963 ± 0.013 and 0.805 ± 0.078 for the bi-exponential and mono-exponential models, respectively. The bi-exponential model also provided a more accurate approximation of real post-exercise oxygen consumption integrals at both 5 min and 15 min. Additionally, variations in V̇O<sub>2_baseline</sub> values had different impacts on key parameters in both models, showing that higher V̇O<sub>2_baseline</sub> values generally improved the model fit in the mono-exponential model but had minimal impact on the bi-exponential model.

Authors

Institutions

Publication Details

Journal
European Journal of Sport Science
Published
2025-04-22
DOI
https://doi.org/10.1002/ejsc.12306
Citations
1
Primary Topic
Cardiovascular and exercise physiology
Type
article
Field-Weighted Citation Impact
2.38

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Post‐Exercise Oxygen Kinetics Modeling With Physiological Bounds and Manual VO2_baseline Input: A Novel Approach

Serhat Özbay, İzzet İnce, Süleyman Ulupınar, Cebrail Gençoğlu et al.
1 citations
European Journal of Sport Science
Cardiovascular and exercise physiology
2.38
article

Enhancing Post‐Exercise Oxygen Kinetics Modeling With Physiological Bounds and Manual VO2_baseline Input: A Novel Approach

Serhat Özbay, İzzet İnce, Süleyman Ulupınar, Cebrail Gençoğlu, Salih Çabuk
article en
1 citations

Abstract

This study addresses a critical limitation in existing computational tools for modeling post-exercise oxygen consumption kinetics (V̇O<sub>2</sub>). Although exponential modeling provides practical insights into recovery dynamics, the inability to incorporate an individual's pre-exercise baseline oxygen consumption value (V̇O<sub>2</sub>_<sub>baseline</sub>) can lead to inaccurate interpretations. A user-defined baseline allows for more precise modeling by aligning recovery kinetics with the true physiological endpoint, representing the individual's actual recovery target after a sufficient rest. To overcome this limitation, this study employs a customized Python algorithm that incorporates user-defined baseline V̇O<sub>2</sub> and uses both mono-exponential and bi-exponential models, aiming to improve upon existing analytical methods. Twenty-two male amateur soccer players participated in this study and performed a 30-s Wingate test. V̇O<sub>2</sub> was measured continuously before, during, and after exercise via a metabolic gas analyzer. Both mono-exponential and bi-exponential models were used to analyze post-exercise V̇O<sub>2</sub> kinetics. The analysis was performed using Origin software (as the reference tool), GedaeLab (a specialized web-based platform), and a custom-developed Python algorithm. The bi-exponential model demonstrated superior fit compared to the mono-exponential model with higher determination coefficient (R<sup>2</sup>) values. Specifically, R<sup>2</sup> values were 0.963 ± 0.013 and 0.805 ± 0.078 for the bi-exponential and mono-exponential models, respectively. The bi-exponential model also provided a more accurate approximation of real post-exercise oxygen consumption integrals at both 5 min and 15 min. Additionally, variations in V̇O<sub>2_baseline</sub> values had different impacts on key parameters in both models, showing that higher V̇O<sub>2_baseline</sub> values generally improved the model fit in the mono-exponential model but had minimal impact on the bi-exponential model.

European Journal of Sport ScienceVol. 25(5)
Erzurum Technical University (TR), Ankara Yıldırım Beyazıt University (TR)
Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
Openalex Percentile: Top 14%
Cardiovascular and exercise physiology
2.38
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.