Multirange Breathing Rate Estimation With Deep Learning Using FMCW Radar

Frequency-Modulated Continuous Wave (FMCW) radar is a promising technology for non-invasive monitoring of vital signs, such as breathing rate (BR). A key challenge lies in selecting the correct range bin corresponding to the human target, particularly in dynamic environments and resource-constrained systems. This paper introduces a resource-efficient deep learning (DL) method for multi-range BR estimation that significantly enhances accuracy while maintaining low computational and memory requirements, making it suitable for embedded systems. We benchmark our method against two alternative single-bin approaches: energy-based and Spatial Phase Coherency (SPC) range-bin selection, both integrated with deep learning for BR estimation. Performance is evaluated on an experimental dataset comprising recordings from 25 subjects, with 17 used for training and 8 for testing. Recordings were conducted under diverse conditions, spanning various distances, angles, sensor mounting heights, and static and dynamic background scenarios, including individuals walking in the background. Our method achieves a Root Mean Square Error (RMSE) of 1.88 breaths per minute (bpm) and a Spearman correlation coefficient of 0.83, outperforming state-of-the-art methods that typically report higher RMSEs on smaller datasets. With a minimal memory footprint of approximately 25 KB, the proposed approach is well-suited for resource-constrained embedded systems. This advancement underscores the potential of lightweight deep learning for reliable and accurate non-invasive vital sign monitoring in healthcare applications.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-04-22
DOI
https://doi.org/10.1109/jsen.2025.3561342
Citations
2
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multirange Breathing Rate Estimation With Deep Learning Using FMCW Radar

Robert Wille, Lorenzo Servadei, Souvik Hazra, Alessandra Fusco et al.
2 citations
IEEE Sensors Journal
Non-Invasive Vital Sign Monitoring
1.35
article

Multirange Breathing Rate Estimation With Deep Learning Using FMCW Radar

Robert Wille, Lorenzo Servadei, Souvik Hazra, Alessandra Fusco, S. Yu. Sakharov, Kostiantyn Lavronenko
article en
2 citations

Abstract

Frequency-Modulated Continuous Wave (FMCW) radar is a promising technology for non-invasive monitoring of vital signs, such as breathing rate (BR). A key challenge lies in selecting the correct range bin corresponding to the human target, particularly in dynamic environments and resource-constrained systems. This paper introduces a resource-efficient deep learning (DL) method for multi-range BR estimation that significantly enhances accuracy while maintaining low computational and memory requirements, making it suitable for embedded systems. We benchmark our method against two alternative single-bin approaches: energy-based and Spatial Phase Coherency (SPC) range-bin selection, both integrated with deep learning for BR estimation. Performance is evaluated on an experimental dataset comprising recordings from 25 subjects, with 17 used for training and 8 for testing. Recordings were conducted under diverse conditions, spanning various distances, angles, sensor mounting heights, and static and dynamic background scenarios, including individuals walking in the background. Our method achieves a Root Mean Square Error (RMSE) of 1.88 breaths per minute (bpm) and a Spearman correlation coefficient of 0.83, outperforming state-of-the-art methods that typically report higher RMSEs on smaller datasets. With a minimal memory footprint of approximately 25 KB, the proposed approach is well-suited for resource-constrained embedded systems. This advancement underscores the potential of lightweight deep learning for reliable and accurate non-invasive vital sign monitoring in healthcare applications.

IEEE Sensors JournalVol. 25(11)
Infineon Technologies (Germany) (DE), Technical University of Munich (DE)
Openalex Percentile: Top 21%
Non-Invasive Vital Sign Monitoring
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.