The Radiation Dosimetry of 68Ga in PET Imaging: Impact of Exposure Pathways and Age on Effective Dose and Organ-Specific Coefficients

The study investigated Positron Emission Tomography (PET), a diagnostic imaging technique employed in healthcare to evaluate physiological functions and detect abnormalities. It emphasized concerns regarding radiation dosimetry and potential risks, advocating for an evaluation of radiopharmaceuticals such as Gallium-68 (68Ga) to prioritize patient safety and prevent radiation exposure. The study determined effective doses and organ-specific dose coefficients, utilizing data from the Federal Guidance Report No. 13 Database (FGR13_DB) and the International Commission on Radiological Protection (ICRP) database, for 68Ga radiopharmaceutical employed in PET imaging, encompassing both internal and external exposure pathways. Younger individuals exhibited greater susceptibility to the effects of radionuclides, with internal exposure leading to significantly higher radiation doses. Consequently, incorporating age-specific coefficients is crucial when assessing the effects and risks associated with radiation exposure. The dose coefficients for 68Ga exhibited variability depending on the exposure scenario. Furthermore, the organs exhibiting the highest sensitivity to radiation were determined based on the specific exposure scenario. For external exposure, the skin, breast surface, and testes were the organs most susceptible to radiation. Regarding internal exposure, the stomach wall and small intestine wall were the organs most affected by ingestion, while the esophagus, stomach wall, and small intestine wall exhibited the highest sensitivity to radiation exposure via inhalation. Concerning the effective dose, it was found that the effective dose is higher when exposure is through ingestion or the dietary route. The collected specific data of dose estimates is important for characterizing patient doses, and specific dosimetric information assists in establishing the risk and optimization of PET.

Institutions

Publication Details

Journal
AlQalam Journal of Medical and Applied Sciences
Published
2025-04-21
DOI
https://doi.org/10.54361/ajmas.258218
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Radiation Dosimetry of 68Ga in PET Imaging: Impact of Exposure Pathways and Age on Effective Dose and Organ-Specific Coefficients

AlQalam Journal of Medical and Applied Sciences
Medical Imaging Techniques and Applications
article

The Radiation Dosimetry of 68Ga in PET Imaging: Impact of Exposure Pathways and Age on Effective Dose and Organ-Specific Coefficients

article en

Abstract

The study investigated Positron Emission Tomography (PET), a diagnostic imaging technique employed in healthcare to evaluate physiological functions and detect abnormalities. It emphasized concerns regarding radiation dosimetry and potential risks, advocating for an evaluation of radiopharmaceuticals such as Gallium-68 (68Ga) to prioritize patient safety and prevent radiation exposure. The study determined effective doses and organ-specific dose coefficients, utilizing data from the Federal Guidance Report No. 13 Database (FGR13_DB) and the International Commission on Radiological Protection (ICRP) database, for 68Ga radiopharmaceutical employed in PET imaging, encompassing both internal and external exposure pathways. Younger individuals exhibited greater susceptibility to the effects of radionuclides, with internal exposure leading to significantly higher radiation doses. Consequently, incorporating age-specific coefficients is crucial when assessing the effects and risks associated with radiation exposure. The dose coefficients for 68Ga exhibited variability depending on the exposure scenario. Furthermore, the organs exhibiting the highest sensitivity to radiation were determined based on the specific exposure scenario. For external exposure, the skin, breast surface, and testes were the organs most susceptible to radiation. Regarding internal exposure, the stomach wall and small intestine wall were the organs most affected by ingestion, while the esophagus, stomach wall, and small intestine wall exhibited the highest sensitivity to radiation exposure via inhalation. Concerning the effective dose, it was found that the effective dose is higher when exposure is through ingestion or the dietary route. The collected specific data of dose estimates is important for characterizing patient doses, and specific dosimetric information assists in establishing the risk and optimization of PET.

AlQalam Journal of Medical and Applied Sciences
Omar Al-Mukhtar University (LY)
Openalex Percentile: Top 87%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.