Mechanical Prostheses in Adults with an Aortic Ring Size of 17–21 mm with and without Posterior Aortoplasty

Introduction. The larger size of the implanted prosthesis provides more favorable conditions for systolic function and more complete regression of left ventricular hypertrophy. In some cases, this can only ensure expansion of the left ventricular outflow tract with a patch. Aim. To compare the immediate results between a group with an isolated mechanical valve replacement inserted into a narrow aortic annulus and a group with a posterior aortoplasty that accommodated a larger mechanical valve. The reasonable proportion of posterior aortoplasty for a narrow ring is 20–30 % of cases. Materials and methods. In 2015–2023, 78 adult patients with a narrow aortic ring (17–21 mm) underwent aortic valve replacement. The isolated prosthetic group consisted of 56 patients, the group with posterior aortoplasty consisted of 22 cases. Results. In the immediate postoperative period, the group with posterior aortoplasty had advantages in: Rashimtoola S.H. index (1,34 ± 0,2 versus 1,06 ± 0,14 см2/м2), significantly lower peak pressure gradient (20,77 ± 6,61 versus 29,33 ± 8,2 mm Hg), mean pressure gradient (10,61 ± 3,23 versus 14,93 ± 4,29 mm Hg) on the prostheses, and left ventricular stroke volume index (29,0 ± 6,56 versus 28,85 ± 7,81 мл/м2). Conclusions. The use of aortoplasty gives better hemodynamic results. The reasonable proportion of posterior aortoplasty for a narrow aortic ring is 28.2 % of cases.

Authors

Publication Details

Journal
Актуальные проблемы медицины
Published
2024-12-30
DOI
https://doi.org/10.52575/2687-0940-2024-47-4-514-531
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanical Prostheses in Adults with an Aortic Ring Size of 17–21 mm with and without Posterior Aortoplasty

Maxim A. Sazonenkov, Khushbakhtdzon H. Ismatov, Andrey S. Moskalev, Andrey M. Tatarintsev et al.
Актуальные проблемы медицины
Cardiac Valve Diseases and Treatments
article

Mechanical Prostheses in Adults with an Aortic Ring Size of 17–21 mm with and without Posterior Aortoplasty

Maxim A. Sazonenkov, Khushbakhtdzon H. Ismatov, Andrey S. Moskalev, Andrey M. Tatarintsev, Ludmila S. Klimenko, Darya D. Moskaleva
article en

Abstract

Introduction. The larger size of the implanted prosthesis provides more favorable conditions for systolic function and more complete regression of left ventricular hypertrophy. In some cases, this can only ensure expansion of the left ventricular outflow tract with a patch. Aim. To compare the immediate results between a group with an isolated mechanical valve replacement inserted into a narrow aortic annulus and a group with a posterior aortoplasty that accommodated a larger mechanical valve. The reasonable proportion of posterior aortoplasty for a narrow ring is 20–30 % of cases. Materials and methods. In 2015–2023, 78 adult patients with a narrow aortic ring (17–21 mm) underwent aortic valve replacement. The isolated prosthetic group consisted of 56 patients, the group with posterior aortoplasty consisted of 22 cases. Results. In the immediate postoperative period, the group with posterior aortoplasty had advantages in: Rashimtoola S.H. index (1,34 ± 0,2 versus 1,06 ± 0,14 см2/м2), significantly lower peak pressure gradient (20,77 ± 6,61 versus 29,33 ± 8,2 mm Hg), mean pressure gradient (10,61 ± 3,23 versus 14,93 ± 4,29 mm Hg) on the prostheses, and left ventricular stroke volume index (29,0 ± 6,56 versus 28,85 ± 7,81 мл/м2). Conclusions. The use of aortoplasty gives better hemodynamic results. The reasonable proportion of posterior aortoplasty for a narrow aortic ring is 28.2 % of cases.

Актуальные проблемы медициныVol. 47(4)
Openalex Percentile: Top 53%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Mechanical Prostheses in Adults with an Aortic Ring Size of 17–21 mm with and without Posterior Aortoplasty — Maxim A. Sazonenkov, Khushbakhtdzon H. Ismatov, et al. · Актуальные проблемы медицины (2024) | TGRS Research Map | TGRS