Time‐Resolved Ratiometric Fluorescence Nanothermometer for Real‐Time Endoscopic Temperature Guidance during Tumor Ablation

Thermal ablation is a common treatment option for early-stage cancers, but the lack of real-time temperature imaging feedback method increases the risk of incomplete or excessive ablation. Although ratiometric nanothermometer offers a rapid temperature imaging solution, accurate in vivo signal extraction remains challenging due to the autofluorescence and wavelength-dependent tissue absorption and scattering. Herein, a time-resolved ratiometric fluorescence nanothermometer composed of europium and iridium complex with identical working wavelength but distinguishing lifetimes is reported, whose well-designed structures enable 450 nm excitation of both complexes with a high quantum yield (57.8%). Based on the nanothermometer, accurate signal extraction is realized in whole blood, beneath a 2 cm tissue phantom and a 5 mm pork slice through a time-resolved ratiometric method. By leveraging the exceptional thermal sensitivity (6.9% K<sup>-1</sup>), high temperature resolution (0.02 K), and clinically relevant temperature range (30-96 °C) of the nanothermometer, a fluorescence temperature endoscopy system is further designed with a real-time temperature imaging speed of 10 fps, which is applied to minimally invasive temperature monitoring during microwave ablation of liver tumors in rabbits, realizing precise ablation control through dynamic ablation power adjustment. The real-time and accurate temperature imaging performance of the nanothermometer may offer a new perspective for intraoperative guidance.

Authors

Institutions

Publication Details

Journal
Advanced Materials
Published
2025-04-21
DOI
https://doi.org/10.1002/adma.202503726
Citations
8
Primary Topic
Nanoplatforms for cancer theranostics
Type
article
Field-Weighted Citation Impact
5.39

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Time‐Resolved Ratiometric Fluorescence Nanothermometer for Real‐Time Endoscopic Temperature Guidance during Tumor Ablation

Donghao Hu, Yiwei Fan, Fuyou Li, Zuqiang Bian et al.
8 citations
Advanced Materials
Nanoplatforms for cancer theranostics
5.39
article

Time‐Resolved Ratiometric Fluorescence Nanothermometer for Real‐Time Endoscopic Temperature Guidance during Tumor Ablation

Donghao Hu, Yiwei Fan, Fuyou Li, Zuqiang Bian, Yuetian Pei, Jiamiao Yin, Zelun Cai, Zhiwei Liu, Lei Chen, Yiran Wang, Huadong Wang, Wenchao Yan, Qingbing Wang
article en
8 citations

Abstract

Thermal ablation is a common treatment option for early-stage cancers, but the lack of real-time temperature imaging feedback method increases the risk of incomplete or excessive ablation. Although ratiometric nanothermometer offers a rapid temperature imaging solution, accurate in vivo signal extraction remains challenging due to the autofluorescence and wavelength-dependent tissue absorption and scattering. Herein, a time-resolved ratiometric fluorescence nanothermometer composed of europium and iridium complex with identical working wavelength but distinguishing lifetimes is reported, whose well-designed structures enable 450 nm excitation of both complexes with a high quantum yield (57.8%). Based on the nanothermometer, accurate signal extraction is realized in whole blood, beneath a 2 cm tissue phantom and a 5 mm pork slice through a time-resolved ratiometric method. By leveraging the exceptional thermal sensitivity (6.9% K<sup>-1</sup>), high temperature resolution (0.02 K), and clinically relevant temperature range (30-96 °C) of the nanothermometer, a fluorescence temperature endoscopy system is further designed with a real-time temperature imaging speed of 10 fps, which is applied to minimally invasive temperature monitoring during microwave ablation of liver tumors in rabbits, realizing precise ablation control through dynamic ablation power adjustment. The real-time and accurate temperature imaging performance of the nanothermometer may offer a new perspective for intraoperative guidance.

Advanced MaterialsVol. 37(28)
Shanghai Jiao Tong University (CN), Peking University (CN), Fudan University (CN), Ruijin Hospital (CN), Shanghai Xuhui Central Hospital (CN)
National Natural Science Foundation of China, Shanghai Jiao Tong University, National Key Research and Development Program of China
Good health and well-being
Openalex Percentile: Top 4%
Nanoplatforms for cancer theranostics
5.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.