On the issue of modeling calibration dependencies of melamine in milk for an infrared analyzer

The article presents the results of modeling the calibration dependence of the melamine content in milk on its concentration in it. Currently, laboratory analysis of milk to determine its physico-chemical parameters using infrared spectrometry is regulated by current regulatory documents that do not provide for the determination of melamine using BIC analyzers, which makes it difficult for them to be used at all stages of milk processing to determine this chemical compound added for the purpose of protein adulteration.The aim of the study was to develop calibration dependencies for the detection of melamine in the milk matrix by near-infrared spectrometry.The research was conducted in stages at the Educational and Research Center for Food and Animal Feed Expertise of the St. Petersburg State University of Veterinary Medicine in 2024.A standard melamine sample, milk without melamine, was used as the study materials.At the first stage, melamine was added to milk samples in different amounts and its concentration was determined by high-performance liquid chromatography, and at the next stage, the IR spectra of the same milk samples were recorded using an infrared analyzer. At the third stage, a statistical analysis of the recorded IR spectra was performed and a calibration model of melamine in milk was constructed using the partial least squares regression method.As a result of the conducted research, a calibration model of the dependence of the quantitative content of melamine on its concentration in milk was constructed. In addition, analyzing the calculated criteria for the constructed calibration relationship, we found that it allows us to reliably determine the concentration of melamine in milk.

Authors

Institutions

Publication Details

Journal
Legal regulation in veterinary medicine
Published
2025-04-21
DOI
https://doi.org/10.52419/issn2782-6252.2025.1.102
Primary Topic
Melamine detection and toxicity
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On the issue of modeling calibration dependencies of melamine in milk for an infrared analyzer

T. V. Kalyuzhnaya
Legal regulation in veterinary medicine
Melamine detection and toxicity
article

On the issue of modeling calibration dependencies of melamine in milk for an infrared analyzer

T. V. Kalyuzhnaya
article en

Abstract

The article presents the results of modeling the calibration dependence of the melamine content in milk on its concentration in it. Currently, laboratory analysis of milk to determine its physico-chemical parameters using infrared spectrometry is regulated by current regulatory documents that do not provide for the determination of melamine using BIC analyzers, which makes it difficult for them to be used at all stages of milk processing to determine this chemical compound added for the purpose of protein adulteration.The aim of the study was to develop calibration dependencies for the detection of melamine in the milk matrix by near-infrared spectrometry.The research was conducted in stages at the Educational and Research Center for Food and Animal Feed Expertise of the St. Petersburg State University of Veterinary Medicine in 2024.A standard melamine sample, milk without melamine, was used as the study materials.At the first stage, melamine was added to milk samples in different amounts and its concentration was determined by high-performance liquid chromatography, and at the next stage, the IR spectra of the same milk samples were recorded using an infrared analyzer. At the third stage, a statistical analysis of the recorded IR spectra was performed and a calibration model of melamine in milk was constructed using the partial least squares regression method.As a result of the conducted research, a calibration model of the dependence of the quantitative content of melamine on its concentration in milk was constructed. In addition, analyzing the calculated criteria for the constructed calibration relationship, we found that it allows us to reliably determine the concentration of melamine in milk.

Legal regulation in veterinary medicine(1)
University of Veterinary Medicine (HU)
Openalex Percentile: Top 91%
Melamine detection and toxicity
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.