Environmental impact of sprinklers and gravity smoke vents interaction — Review and probabilistic modelling approach

In the event of a fire in a typical industrial building, the systems deployed first are sprinklers and gravity smoke vents. Scientists and experts have not reached a firm consensus on the advantages or disadvantages of using sprinklers and gravity smoke vents together. While life-safety and property protection aspects have been already investigated, the environmental impact of these interactions has not yet been considered in research. This study identified and meticulously analysed several environmental issues related to the cooperation of these FPSs. A probabilistic model was then developed to efficiently assess emissions of selected pollutants from fires. The focus was on priority pollutants in terms of climate, toxicity and carcinogenicity . Various cost-optimization and monetization techniques were assessed to propose an appropriate method for evaluating the environmental impact of FPSs. A generic warehouse case study was conducted, comparing 24 different storage and FPS configurations. The applicability of the proposed approach was confirmed; however, the case study results indicates that the interference between sprinklers and gravity smoke vents is relatively insignificant compared to other factors. Additionally, four configurations of sprinklers and vents application were analysed. Sprinklers only have the lowest impact on environment for generic warehouse. • A probabilistic model including sprinklers and smoke vents interference was developed. • New method for optimizing fire protection systems based on environmental expense. • The impact of sprinklers and smoke vent systems mutual interaction is marginal. • Sprinklers application is more environmentally viable than vents or both systems.

Authors

Institutions

Publication Details

Journal
Fire Safety Journal
Published
2025-04-21
DOI
https://doi.org/10.1016/j.firesaf.2025.104386
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Environmental impact of sprinklers and gravity smoke vents interaction — Review and probabilistic modelling approach

Adam Krasuski, Wioletta Rogula–Kozłowska, Wojciech Kowalski
Fire Safety Journal
Fire dynamics and safety research
article

Environmental impact of sprinklers and gravity smoke vents interaction — Review and probabilistic modelling approach

Adam Krasuski, Wioletta Rogula–Kozłowska, Wojciech Kowalski
article en

Abstract

In the event of a fire in a typical industrial building, the systems deployed first are sprinklers and gravity smoke vents. Scientists and experts have not reached a firm consensus on the advantages or disadvantages of using sprinklers and gravity smoke vents together. While life-safety and property protection aspects have been already investigated, the environmental impact of these interactions has not yet been considered in research. This study identified and meticulously analysed several environmental issues related to the cooperation of these FPSs. A probabilistic model was then developed to efficiently assess emissions of selected pollutants from fires. The focus was on priority pollutants in terms of climate, toxicity and carcinogenicity . Various cost-optimization and monetization techniques were assessed to propose an appropriate method for evaluating the environmental impact of FPSs. A generic warehouse case study was conducted, comparing 24 different storage and FPS configurations. The applicability of the proposed approach was confirmed; however, the case study results indicates that the interference between sprinklers and gravity smoke vents is relatively insignificant compared to other factors. Additionally, four configurations of sprinklers and vents application were analysed. Sprinklers only have the lowest impact on environment for generic warehouse. • A probabilistic model including sprinklers and smoke vents interference was developed. • New method for optimizing fire protection systems based on environmental expense. • The impact of sprinklers and smoke vent systems mutual interaction is marginal. • Sprinklers application is more environmentally viable than vents or both systems.

Fire Safety JournalVol. 154
Akademia Pożarnicza (PL)
Climate action
Openalex Percentile: Top 91%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Environmental impact of sprinklers and gravity smoke vents interaction — Review and probabilistic modelling approach — Adam Krasuski, Wioletta Rogula–Kozłowska, et al. · Fire Safety Journal (2025) | TGRS Research Map | TGRS