Measurement and suppression of tensor light shift for nonlinear magneto-optical rotating atomic magnetometers

In the NMOR atomic magnetometer , the tensor light shift is identified as a critical systemic error that affects the accuracy of magnetic resonance frequency measurements. In this paper, we present a tensor light shift measurement and suppression method based on Linear Resonance Frequency Variation and Reverse Magnetic Compensation (LRFV-RMC), which utilizes the resonance frequency linear dependence on the light shift, along with a suppression technique based on reverse magnetic compensation. To further enhance the compensation accuracy and improve the long-term stability of magnetic field measurement, a closed-loop light power control scheme is introduced. The theoretical models of resonant frequency and tensor light shift are established and the mechanism of the influence of light shift on resonance frequency is clarified. Additionally, the light shift and its corresponding magnetic resonance signals are investigated theoretically and experimentally under different light power, polarization direction and magnetic field amplitude . As a result, compared to the existing system, the proposed method effectively compensates for tensor light shift and improves the long-term stability of the magnetic resonance signal by at least 25.8%. This work provides a practical approach to improving the accuracy and stability of NMOR atomic magnetometers. • A method to determine tensor light shift via magnetic resonance at varying power. • Theoretical models of system response and tensor light shift are developed. • A method using reverse magnetic field to suppress tensor light shift is proposed. • An optical power stabilization scheme is proposed to eliminate compensation error.

Authors

Institutions

Publication Details

Journal
Sensors and Actuators A Physical
Published
2025-04-21
DOI
https://doi.org/10.1016/j.sna.2025.116562
Citations
1
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
1.25
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement and suppression of tensor light shift for nonlinear magneto-optical rotating atomic magnetometers

Junlin Chen, Zhenglong Lu, Xin Zhao, Liwei Jiang et al.
1 citations
Sensors and Actuators A Physical
Atomic and Subatomic Physics Research
1.25
article

Measurement and suppression of tensor light shift for nonlinear magneto-optical rotating atomic magnetometers

Junlin Chen, Zhenglong Lu, Xin Zhao, Liwei Jiang, Jiali Liu, Wei Quan, Yanchao Chai, Mengnan Tian
article en
1 citations

Abstract

In the NMOR atomic magnetometer , the tensor light shift is identified as a critical systemic error that affects the accuracy of magnetic resonance frequency measurements. In this paper, we present a tensor light shift measurement and suppression method based on Linear Resonance Frequency Variation and Reverse Magnetic Compensation (LRFV-RMC), which utilizes the resonance frequency linear dependence on the light shift, along with a suppression technique based on reverse magnetic compensation. To further enhance the compensation accuracy and improve the long-term stability of magnetic field measurement, a closed-loop light power control scheme is introduced. The theoretical models of resonant frequency and tensor light shift are established and the mechanism of the influence of light shift on resonance frequency is clarified. Additionally, the light shift and its corresponding magnetic resonance signals are investigated theoretically and experimentally under different light power, polarization direction and magnetic field amplitude . As a result, compared to the existing system, the proposed method effectively compensates for tensor light shift and improves the long-term stability of the magnetic resonance signal by at least 25.8%. This work provides a practical approach to improving the accuracy and stability of NMOR atomic magnetometers. • A method to determine tensor light shift via magnetic resonance at varying power. • Theoretical models of system response and tensor light shift are developed. • A method using reverse magnetic field to suppress tensor light shift is proposed. • An optical power stabilization scheme is proposed to eliminate compensation error.

Sensors and Actuators A PhysicalVol. 390
Hefei University (CN), Zhejiang Lab (CN), Beihang University (CN)
Affordable and clean energy
Openalex Percentile: Top 22%
Atomic and Subatomic Physics Research
1.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.