Average Current Mode Control of Grid Connected Voltage Source Inverters with LCL Filter

This paper presents the average current mode control of single-phase grid-connected inverters without explicitly using an analog loop filter. The reference and the feedback inverter currents are given to a comparator instead of a subtractor. The duty cycle of the comparator output waveform is then estimated and compared against a reference duty cycle of 50% to obtain the error signal for the PI current controller. The PI controller output added with the grid voltage feed-forward term drives the PWM module to generate H-bridge switching pulses. The paper analyses the effect of using the comparator and associated logic instead of directly employing a subtractor to generate a current error signal for the control loop. The proposed method provides a robust current sensing scheme, shielding the current control loop from high-frequency common mode leakage currents and switching harmonics, and delivers grid current with a low THD of 0.83%. A scheme to further reduce the THD of the grid current by compensating for the dead-time is also investigated and the THD of the grid current could be further lowered to 0.17%.

Authors

Publication Details

Published
2025-02-07
DOI
https://doi.org/10.1109/etis64005.2025.10961846
Citations
1
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
1.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Average Current Mode Control of Grid Connected Voltage Source Inverters with LCL Filter

K. Mathew, Nithin James, Bos Mathew Jos
1 citations
Microgrid Control and Optimization
1.21
article

Average Current Mode Control of Grid Connected Voltage Source Inverters with LCL Filter

K. Mathew, Nithin James, Bos Mathew Jos
article en
1 citations

Abstract

This paper presents the average current mode control of single-phase grid-connected inverters without explicitly using an analog loop filter. The reference and the feedback inverter currents are given to a comparator instead of a subtractor. The duty cycle of the comparator output waveform is then estimated and compared against a reference duty cycle of 50% to obtain the error signal for the PI current controller. The PI controller output added with the grid voltage feed-forward term drives the PWM module to generate H-bridge switching pulses. The paper analyses the effect of using the comparator and associated logic instead of directly employing a subtractor to generate a current error signal for the control loop. The proposed method provides a robust current sensing scheme, shielding the current control loop from high-frequency common mode leakage currents and switching harmonics, and delivers grid current with a low THD of 0.83%. A scheme to further reduce the THD of the grid current by compensating for the dead-time is also investigated and the THD of the grid current could be further lowered to 0.17%.

Affordable and clean energy
Openalex Percentile: Top 22%
Microgrid Control and Optimization
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Average Current Mode Control of Grid Connected Voltage Source Inverters with LCL Filter — K. Mathew, Nithin James, et al. · (2025) | TGRS Research Map | TGRS