Soft Switched Common Ground Transformerless Single Phase PV Inverter

Soft-switching techniques are employed in compact photovoltaic transformer-less inverters (TLIs) which operates at high switching frequencies. Inverters which comply to recent technical standards like IEEE1547 needs to have a greater power factor operation range so that it can support the utility grid during sag and swell conditions. However, many of the existing soft-switched TLIs are meant to work at unity power factor only. Some of the recently proposed H-bridge derived TLI topologies which support full power factor (FPF) operation is built with more number of auxiliary switches and this increases the complexity of the inverter. In this paper a zero-voltage transition (ZVT) common ground (CG) transformer-less inverter is proposed where soft-switching is achieved for FPF operation with only four additional auxiliary switches. This scheme ensures zero voltage turn-on and turn-off for the main switches and zero-current turn-on for the auxiliary switches.

Authors

Institutions

Publication Details

Published
2024-12-18
DOI
https://doi.org/10.1109/pedes61459.2024.10961508
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Soft Switched Common Ground Transformerless Single Phase PV Inverter

E. S. Sreeraj, Raghavendra Bandaru, Puneet K. Goel, Prajyoth Gaonkar
Multilevel Inverters and Converters
article

Soft Switched Common Ground Transformerless Single Phase PV Inverter

E. S. Sreeraj, Raghavendra Bandaru, Puneet K. Goel, Prajyoth Gaonkar
article en

Abstract

Soft-switching techniques are employed in compact photovoltaic transformer-less inverters (TLIs) which operates at high switching frequencies. Inverters which comply to recent technical standards like IEEE1547 needs to have a greater power factor operation range so that it can support the utility grid during sag and swell conditions. However, many of the existing soft-switched TLIs are meant to work at unity power factor only. Some of the recently proposed H-bridge derived TLI topologies which support full power factor (FPF) operation is built with more number of auxiliary switches and this increases the complexity of the inverter. In this paper a zero-voltage transition (ZVT) common ground (CG) transformer-less inverter is proposed where soft-switching is achieved for FPF operation with only four additional auxiliary switches. This scheme ensures zero voltage turn-on and turn-off for the main switches and zero-current turn-on for the auxiliary switches.

National Institute of Technology Goa (IN)
Affordable and clean energy
Openalex Percentile: Top 73%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.