Open Circuit Fault-Tolerant Two-Level STATCOM with Balanced Line Currents

Three phase Static Compensators (STATCOM) using Pulse Width Modulated (PWM) converters are widely used for shunt compensation in transmission lines. In case only two of the STATCOM legs remain connected to the grid due to an open circuit fault in one of its legs or line reactors, existing fault-tolerant schemes cannot continue operation with balanced grid side line currents. A new scheme is presented in this paper in which the STATCOM can continue operation during single line open circuit fault and inject balanced line currents, without additional redundant leg or switches. The proposed fault-tolerant technique adjusts the phase shift between the current in the two operative leg of the STATCOM and uses a full VA rated delta-star coupling/isolation transformer to inject balanced VAr into the grid. This arrangement provides a simple solution for incorporating fault-tolerant capability during design of 3-leg STATCOM. Simulation and experimental results are presented to validate the proposed scheme.

Authors

Institutions

Publication Details

Published
2024-12-18
DOI
https://doi.org/10.1109/pedes61459.2024.10961850
Primary Topic
Semiconductor materials and devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Open Circuit Fault-Tolerant Two-Level STATCOM with Balanced Line Currents

Koustuv Sarkar, Sujit K. Biswas, Susovan Mukhopadhyay, Dipten Maiti et al.
Semiconductor materials and devices
article

Open Circuit Fault-Tolerant Two-Level STATCOM with Balanced Line Currents

Koustuv Sarkar, Sujit K. Biswas, Susovan Mukhopadhyay, Dipten Maiti, Abanishwar Chakrabarti, Soham Chakraborty
article en

Abstract

Three phase Static Compensators (STATCOM) using Pulse Width Modulated (PWM) converters are widely used for shunt compensation in transmission lines. In case only two of the STATCOM legs remain connected to the grid due to an open circuit fault in one of its legs or line reactors, existing fault-tolerant schemes cannot continue operation with balanced grid side line currents. A new scheme is presented in this paper in which the STATCOM can continue operation during single line open circuit fault and inject balanced line currents, without additional redundant leg or switches. The proposed fault-tolerant technique adjusts the phase shift between the current in the two operative leg of the STATCOM and uses a full VA rated delta-star coupling/isolation transformer to inject balanced VAr into the grid. This arrangement provides a simple solution for incorporating fault-tolerant capability during design of 3-leg STATCOM. Simulation and experimental results are presented to validate the proposed scheme.

Jadavpur University (IN), National Institute of Technology Agartala (IN), Indian Institute of Technology Gandhinagar (IN), Netaji Subhas University of Technology (IN)
Climate action
Openalex Percentile: Top 73%
Semiconductor materials and devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.