Integral Dual Fractional Derivative Frequency Controller for Thermal Power Plant with Delay

Time delays in power systems cause phase lag and impair closed-loop stability, which worsen the performance of load frequency control (LFC). So as to accomplish increased resilience, this work suggests an analytical design of an integral dual fractional derivative (IDFD) controller with a single tuneable parameter for an isolated time-delayed microgrid. The controller's sole tuning parameter is intended to accomplish a satisfactory trade-off between resilience and performance. The findings of the simulation confirm that the suggested design is more resilient than some of its counterparts. In the face of nonlinearities, abrupt changes in load, and uncertainties in system parameters, the competency of proposed controller is assessed.

Authors

Institutions

Publication Details

Published
2024-12-18
DOI
https://doi.org/10.1109/pedes61459.2024.10960886
Citations
6
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
1.25
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integral Dual Fractional Derivative Frequency Controller for Thermal Power Plant with Delay

Utkal Ranjan Muduli, Mohamed Alkhatib, Khalifa Al Hosani, Deepak Kumar et al.
6 citations
Frequency Control in Power Systems
1.25
article

Integral Dual Fractional Derivative Frequency Controller for Thermal Power Plant with Delay

Utkal Ranjan Muduli, Mohamed Alkhatib, Khalifa Al Hosani, Deepak Kumar, G. Lloyds Raja, Omar Al Zaabi
article en
6 citations

Abstract

Time delays in power systems cause phase lag and impair closed-loop stability, which worsen the performance of load frequency control (LFC). So as to accomplish increased resilience, this work suggests an analytical design of an integral dual fractional derivative (IDFD) controller with a single tuneable parameter for an isolated time-delayed microgrid. The controller's sole tuning parameter is intended to accomplish a satisfactory trade-off between resilience and performance. The findings of the simulation confirm that the suggested design is more resilient than some of its counterparts. In the face of nonlinearities, abrupt changes in load, and uncertainties in system parameters, the competency of proposed controller is assessed.

National Institute of Technology Patna (IN), Khalifa University of Science and Technology (AE), United Arab Emirates University (AE)
Affordable and clean energy
Openalex Percentile: Top 19%
Frequency Control in Power Systems
1.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Integral Dual Fractional Derivative Frequency Controller for Thermal Power Plant with Delay — Utkal Ranjan Muduli, Mohamed Alkhatib, et al. · (2024) | TGRS Research Map | TGRS