Optimized Dual Phase Shift Control for Dual Active Bridge DC-DC Converter

The Dual Active Bridge (DAB) converter is widely recognized for its applicability in high-power applications, offering features such as high-power density, inherent soft switching, modularity, galvanic isolation, bi-directional power flow, and high-frequency operation. Typically, the DAB converter is controlled using the traditional Single-Phase Shift (SPS) method. However, this control method can lead to a peak inductor current when there is a voltage disparity across the inductor, negatively impacting the performance of the converter. To address this issue, an optimized Dual Phase Shift (DPS) control technique has been introduced. This optimized DPS control not only minimizes the peak inductor current required to achieve the desired power but also reduces the RMS current flowing through the magnetic components, thereby enhancing the overall performance of the converter.

Authors

Institutions

Publication Details

Published
2024-12-18
DOI
https://doi.org/10.1109/pedes61459.2024.10961877
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimized Dual Phase Shift Control for Dual Active Bridge DC-DC Converter

Aditya Kulkarni, Saurabh Kamble, Pradyumn Chaturvedi, Harish Bhawane
Advanced DC-DC Converters
article

Optimized Dual Phase Shift Control for Dual Active Bridge DC-DC Converter

Aditya Kulkarni, Saurabh Kamble, Pradyumn Chaturvedi, Harish Bhawane
article en

Abstract

The Dual Active Bridge (DAB) converter is widely recognized for its applicability in high-power applications, offering features such as high-power density, inherent soft switching, modularity, galvanic isolation, bi-directional power flow, and high-frequency operation. Typically, the DAB converter is controlled using the traditional Single-Phase Shift (SPS) method. However, this control method can lead to a peak inductor current when there is a voltage disparity across the inductor, negatively impacting the performance of the converter. To address this issue, an optimized Dual Phase Shift (DPS) control technique has been introduced. This optimized DPS control not only minimizes the peak inductor current required to achieve the desired power but also reduces the RMS current flowing through the magnetic components, thereby enhancing the overall performance of the converter.

Visvesvaraya National Institute of Technology (IN)
Affordable and clean energy
Openalex Percentile: Top 73%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.