Magnetic Particle Imaging Using an Optically Pumped Magnetometer Coupled With a Flux Transformer

We propose a magnetic particle imaging (MPI) scanner using an optically pumped magnetometer (OPM) that is connected via a flux transformer. The OPM has high sensitivity, but it cannot operate in the excitation magnetic field used to magnetize the magnetic nanoparticles because of its narrow dynamic range. As a result, a flux transformer is used in this work to overcome the problem. Furthermore, the excitation current amplitude was maintained at a constant level using real-time feedback control and wavelet denoising was used to reduce the measurement noise. The results demonstrate that the position of a 100 μg-Fe Resovist magnetic nanoparticle sample can be estimated successfully via an inverse problem analysis approach to within an error of 5 mm even when the sample is located at depths of 25–50 mm from the pickup coil.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3563034
Citations
1
Primary Topic
Characterization and Applications of Magnetic Nanoparticles
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Magnetic Particle Imaging Using an Optically Pumped Magnetometer Coupled With a Flux Transformer

Takashi Yoshida, Teruyoshi Sasayama, Shuji Taue
1 citations
IEEE Transactions on Instrumentation and Measurement
Characterization and Applications of Magnetic Nanoparticles
0.67
article

Magnetic Particle Imaging Using an Optically Pumped Magnetometer Coupled With a Flux Transformer

Takashi Yoshida, Teruyoshi Sasayama, Shuji Taue
article en
1 citations

Abstract

We propose a magnetic particle imaging (MPI) scanner using an optically pumped magnetometer (OPM) that is connected via a flux transformer. The OPM has high sensitivity, but it cannot operate in the excitation magnetic field used to magnetize the magnetic nanoparticles because of its narrow dynamic range. As a result, a flux transformer is used in this work to overcome the problem. Furthermore, the excitation current amplitude was maintained at a constant level using real-time feedback control and wavelet denoising was used to reduce the measurement noise. The results demonstrate that the position of a 100 μg-Fe Resovist magnetic nanoparticle sample can be estimated successfully via an inverse problem analysis approach to within an error of 5 mm even when the sample is located at depths of 25–50 mm from the pickup coil.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Kyushu University (JP), Kochi University of Technology (JP)
Affordable and clean energy
Openalex Percentile: Top 33%
Characterization and Applications of Magnetic Nanoparticles
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Magnetic Particle Imaging Using an Optically Pumped Magnetometer Coupled With a Flux Transformer — Takashi Yoshida, Teruyoshi Sasayama, et al. · IEEE Transactions on Instrumentation and Measurement (2025) | TGRS Research Map | TGRS