Enhancing Ancillary Grid Services with Integrated PV System under Unbalanced Load and Weak Grid Scenario

The paper introduces a grid-connected ancillary photovoltaic (PV) system that supplies power to the grid and a nonlinear load. It employs a Third Order Generalized Integrator Quadrature Signal Generator (TOGI-QSG) control for a D-STATCOM type Voltage Source Converter (VSC). In comparison with conventional control algorithms, it ensure symmetrically balanced grid currents, unity power factor correction, and harmonic mitigation, even under conditions such as unbalanced nonlinear loads, fluctuations in solar irradiation, and disturbances in grid voltage. The Maximum Power Point Tracking (MPPT) algorithm, based on Perturb and Observe (P&O), is utilized to maximize power extraction from the solar photovoltaic array. The real-time performance of the system is evaluated using the Opal-RT OP4510 simulator across diverse operational scenarios, including load imbalances, sudden changes in solar irradiance. The work adheres strictly to revised harmonic control standards such as IEEE std. 519 and IEC std. 62109.

Authors

Institutions

Publication Details

Published
2024-12-18
DOI
https://doi.org/10.1109/pedes61459.2024.10961195
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Ancillary Grid Services with Integrated PV System under Unbalanced Load and Weak Grid Scenario

Vedantham Lakshmi Srinivas, Pranay Krishna Sahay
Microgrid Control and Optimization
article

Enhancing Ancillary Grid Services with Integrated PV System under Unbalanced Load and Weak Grid Scenario

Vedantham Lakshmi Srinivas, Pranay Krishna Sahay
article en

Abstract

The paper introduces a grid-connected ancillary photovoltaic (PV) system that supplies power to the grid and a nonlinear load. It employs a Third Order Generalized Integrator Quadrature Signal Generator (TOGI-QSG) control for a D-STATCOM type Voltage Source Converter (VSC). In comparison with conventional control algorithms, it ensure symmetrically balanced grid currents, unity power factor correction, and harmonic mitigation, even under conditions such as unbalanced nonlinear loads, fluctuations in solar irradiation, and disturbances in grid voltage. The Maximum Power Point Tracking (MPPT) algorithm, based on Perturb and Observe (P&O), is utilized to maximize power extraction from the solar photovoltaic array. The real-time performance of the system is evaluated using the Opal-RT OP4510 simulator across diverse operational scenarios, including load imbalances, sudden changes in solar irradiance. The work adheres strictly to revised harmonic control standards such as IEEE std. 519 and IEC std. 62109.

Indian Institute of Technology Dhanbad (IN)
Openalex Percentile: Top 63%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enhancing Ancillary Grid Services with Integrated PV System under Unbalanced Load and Weak Grid Scenario — Vedantham Lakshmi Srinivas, Pranay Krishna Sahay · (2024) | TGRS Research Map | TGRS