A Cyber-Resilient Control Scheme for AGC of Hydropower System

A cyberattack is designed to destabilize a system connected through a communication network. While ongoing research focuses on attack detection algorithms, it is crucial to have a robust control mechanism in place to address the possibility of undiscovered security compromise events persisting for a significant duration. Resiliency is particularly important for a controller engaged in automated generation control (AGC), since it must be able to function effectively even in abnormal conditions, without the option of shutting down operations. This research presents a novel method to assist hydrothermal power systems in dealing with network-related obstacles such as communication latency (CL) and attacks. We present a novel tri-parametric fractional controller (TFC) that combines the benefits of proportional-integral and proportional-derivative operations. This eliminates the requirement for extra control loops. The resiliency of suggested TFC is illustrated by performing simulation studies on benchmark attack models.

Authors

Institutions

Publication Details

Published
2024-12-18
DOI
https://doi.org/10.1109/pedes61459.2024.10961752
Citations
1
Primary Topic
Smart Grid Security and Resilience
Type
article
Field-Weighted Citation Impact
0.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Cyber-Resilient Control Scheme for AGC of Hydropower System

Thanga Raj Chelliah, Pulakraj Aryan
1 citations
Smart Grid Security and Resilience
0.33
article

A Cyber-Resilient Control Scheme for AGC of Hydropower System

Thanga Raj Chelliah, Pulakraj Aryan
article en
1 citations

Abstract

A cyberattack is designed to destabilize a system connected through a communication network. While ongoing research focuses on attack detection algorithms, it is crucial to have a robust control mechanism in place to address the possibility of undiscovered security compromise events persisting for a significant duration. Resiliency is particularly important for a controller engaged in automated generation control (AGC), since it must be able to function effectively even in abnormal conditions, without the option of shutting down operations. This research presents a novel method to assist hydrothermal power systems in dealing with network-related obstacles such as communication latency (CL) and attacks. We present a novel tri-parametric fractional controller (TFC) that combines the benefits of proportional-integral and proportional-derivative operations. This eliminates the requirement for extra control loops. The resiliency of suggested TFC is illustrated by performing simulation studies on benchmark attack models.

Indian Institute of Technology Roorkee (IN)
Climate action
Openalex Percentile: Top 36%
Smart Grid Security and Resilience
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.