A Novel Signal Processing and Deep Learning Approach for Fault Diagnosis in Grid Integrated AC Microgrid

A novel approach for microgrid (MG) protection, utilizing Empirical Mode Decomposition (EMD) and Deep Convolutional Neural Networks (DCNN), is proposed to enhance fault detection for improved reliability and safety. The method applies EMD to decompose the raw signals into distinct intrinsic mode functions (IMFs) across various frequency scales, followed by signal reconstruction based on key IMFs that capture transient characteristics. These reconstructed signals are transformed into 2D scalogram images, which serve as input to the DCNN, allowing the model to extract both temporal and frequency-based features for comprehensive fault analysis. By combining EMD with DCNN, the proposed EMD-DCNN method achieves improved accuracy and reliability in detecting shunt and series faults in grid-connected microgrids, with simulations carried out in the MATLAB/Simulink environment.

Authors

Institutions

Publication Details

Published
2024-12-18
DOI
https://doi.org/10.1109/pedes61459.2024.10961221
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Signal Processing and Deep Learning Approach for Fault Diagnosis in Grid Integrated AC Microgrid

Ranjan Kumar Mallick, Anasuya Roy Choudhury, Debadatta Amaresh Gadanayak, Pravati Nayak et al.
Power Systems Fault Detection
article

A Novel Signal Processing and Deep Learning Approach for Fault Diagnosis in Grid Integrated AC Microgrid

Ranjan Kumar Mallick, Anasuya Roy Choudhury, Debadatta Amaresh Gadanayak, Pravati Nayak, Nityananda Giri, Sairam Mishra
article en

Abstract

A novel approach for microgrid (MG) protection, utilizing Empirical Mode Decomposition (EMD) and Deep Convolutional Neural Networks (DCNN), is proposed to enhance fault detection for improved reliability and safety. The method applies EMD to decompose the raw signals into distinct intrinsic mode functions (IMFs) across various frequency scales, followed by signal reconstruction based on key IMFs that capture transient characteristics. These reconstructed signals are transformed into 2D scalogram images, which serve as input to the DCNN, allowing the model to extract both temporal and frequency-based features for comprehensive fault analysis. By combining EMD with DCNN, the proposed EMD-DCNN method achieves improved accuracy and reliability in detecting shunt and series faults in grid-connected microgrids, with simulations carried out in the MATLAB/Simulink environment.

Siksha O Anusandhan University (IN)
Openalex Percentile: Top 63%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies