Harmonic Profile of Various Loads Used in Distribution System of Qatar Utility

This paper presents a comprehensive investigation of the harmonic profiles and total harmonic distortion (THD) of individual Qatari household loads, both dominant and non-dominant. The study analyses the harmonic characteristics of major appliances such as refrigerators, air conditioners and televisions. It reveals a significant THD of 65.12%, indicating significant harmonic contributions from these dominant loads. At the same time, a more modest THD of 13.71%, indicating a comparatively cleaner harmonic signature, is shown for non-dominant loads such as LED lamps, washing machines and hairdryers. The paper also looks at the specific harmonic components generated by each load, shedding light on the distinctive nature of their harmonic distortions. Highlighting the collective influence of both dominant and non-dominant loads on overall power quality, the cumulative THD for all domestic loads is measured at 30.36%.

Authors

Institutions

Publication Details

Published
2024-12-18
DOI
https://doi.org/10.1109/pedes61459.2024.10961225
Primary Topic
Vibration and Dynamic Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Harmonic Profile of Various Loads Used in Distribution System of Qatar Utility

Farhad Ilahi Bakhsh, Shirazul Islam, Chemidi Abdelkarim
Vibration and Dynamic Analysis
article

Harmonic Profile of Various Loads Used in Distribution System of Qatar Utility

Farhad Ilahi Bakhsh, Shirazul Islam, Chemidi Abdelkarim
article en

Abstract

This paper presents a comprehensive investigation of the harmonic profiles and total harmonic distortion (THD) of individual Qatari household loads, both dominant and non-dominant. The study analyses the harmonic characteristics of major appliances such as refrigerators, air conditioners and televisions. It reveals a significant THD of 65.12%, indicating significant harmonic contributions from these dominant loads. At the same time, a more modest THD of 13.71%, indicating a comparatively cleaner harmonic signature, is shown for non-dominant loads such as LED lamps, washing machines and hairdryers. The paper also looks at the specific harmonic components generated by each load, shedding light on the distinctive nature of their harmonic distortions. Highlighting the collective influence of both dominant and non-dominant loads on overall power quality, the cumulative THD for all domestic loads is measured at 30.36%.

École Supérieure en Sciences Appliquées de Tlemcen (DZ), Qatar University (QA), National Institute of Technology Srinagar (IN)
Affordable and clean energy
Openalex Percentile: Top 63%
Vibration and Dynamic Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Harmonic Profile of Various Loads Used in Distribution System of Qatar Utility — Farhad Ilahi Bakhsh, Shirazul Islam, et al. · (2024) | TGRS Research Map | TGRS