With the influx of nonlinear loads into the power system, there is a need to mitigate the effects of harmonic current drawn by the loads under standalone inverter systems. Filters are ineffective in mitigating lower-order harmonics. Hence, improve-ments in control schemes have to be implemented to improve the voltage quality. In this paper, an Inductor Current Feed-forward (ICF) based single-loop dq (SLdq) control scheme is proposed to suppress the effects of the harmonics. The proposed controller is developed through dq frame modelling and is compared with the existing SLdq control scheme. It is shown through simulations and hardware experimentation that the ICF-based SLdq control scheme is superior to the SLdq control.

Authors

Institutions

Publication Details

Published
2024-12-18
DOI
https://doi.org/10.1109/pedes61459.2024.10960964
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Inductor Current Feed-Forward Based Single-Loop DQ Control Scheme for Standalone Inverter System

Cilaveni Satish Chandra, Ravindranath Adda, Vaishnavvignesh G Iyer, J G Sreenath
Multilevel Inverters and Converters
article

Inductor Current Feed-Forward Based Single-Loop DQ Control Scheme for Standalone Inverter System

Cilaveni Satish Chandra, Ravindranath Adda, Vaishnavvignesh G Iyer, J G Sreenath
article en

Abstract

With the influx of nonlinear loads into the power system, there is a need to mitigate the effects of harmonic current drawn by the loads under standalone inverter systems. Filters are ineffective in mitigating lower-order harmonics. Hence, improve-ments in control schemes have to be implemented to improve the voltage quality. In this paper, an Inductor Current Feed-forward (ICF) based single-loop dq (SLdq) control scheme is proposed to suppress the effects of the harmonics. The proposed controller is developed through dq frame modelling and is compared with the existing SLdq control scheme. It is shown through simulations and hardware experimentation that the ICF-based SLdq control scheme is superior to the SLdq control.

Indian Institute of Technology Guwahati (IN)
Science and Engineering Research Board
Affordable and clean energy
Openalex Percentile: Top 73%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Inductor Current Feed-Forward Based Single-Loop DQ Control Scheme for Standalone Inverter System — Cilaveni Satish Chandra, Ravindranath Adda, et al. · (2024) | TGRS Research Map | TGRS