A Seven-Level Triple Boost Common Ground Inverter Without H-Bridge

In solar photovoltaic (PV) systems, inverters without transformers are extensively accepted because of their high-power density, decreased <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{dv}/\text{dt}$</tex> stress, affordability and enhanced performance. However, leakage current through the ground is a primary issue with transformer-less inverters. This study introduces a modified 7-level common-ground (CG) transformer-less inverter without an H-bridge and with a reduced number of components. It employs switched capacitors (SC) with a single source input to generate a seven-level output, achieving a threefold voltage gain and eliminating ground leakage current via the CG connection. The SC voltages are balanced naturally in each cycle, avoiding the need for sensors or complex controls. The inverter's performance is validated through MATLAB/Simulink simulations and experimental testing, including thermal modelling in PLECS to evaluate efficiency and power losses. Simulation and experimental results confirm the working of the proposed topology.

Authors

Institutions

Publication Details

Published
2024-12-18
DOI
https://doi.org/10.1109/pedes61459.2024.10961825
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Seven-Level Triple Boost Common Ground Inverter Without H-Bridge

Atif Iqbal, M. A. Bhat, Mohd. Anas Anees, Saad Mekhilef et al.
Multilevel Inverters and Converters
article

A Seven-Level Triple Boost Common Ground Inverter Without H-Bridge

Atif Iqbal, M. A. Bhat, Mohd. Anas Anees, Saad Mekhilef, Adil Sarwar, Mohammad Zaid
article en

Abstract

In solar photovoltaic (PV) systems, inverters without transformers are extensively accepted because of their high-power density, decreased <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{dv}/\text{dt}$</tex> stress, affordability and enhanced performance. However, leakage current through the ground is a primary issue with transformer-less inverters. This study introduces a modified 7-level common-ground (CG) transformer-less inverter without an H-bridge and with a reduced number of components. It employs switched capacitors (SC) with a single source input to generate a seven-level output, achieving a threefold voltage gain and eliminating ground leakage current via the CG connection. The SC voltages are balanced naturally in each cycle, avoiding the need for sensors or complex controls. The inverter's performance is validated through MATLAB/Simulink simulations and experimental testing, including thermal modelling in PLECS to evaluate efficiency and power losses. Simulation and experimental results confirm the working of the proposed topology.

Aligarh Muslim University (IN), University of Malaya (MY), Swinburne University of Technology (AU), Qatar University (QA)
Affordable and clean energy
Openalex Percentile: Top 73%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Seven-Level Triple Boost Common Ground Inverter Without H-Bridge — Atif Iqbal, M. A. Bhat, et al. · (2024) | TGRS Research Map | TGRS