Intranasal parainfluenza virus-vectored vaccine expressing SARS-CoV-2 spike protein of Delta or Omicron B.1.1.529 induces mucosal and systemic immunity and protects hamsters against homologous and heterologous challenge

The continuous emergence of new SARS-CoV-2 variants requires that COVID vaccines be updated to match circulating strains. We generated B/HPIV3-vectored vaccines expressing 6P-stabilized S protein of the ancestral, B.1.617.2/Delta, or B.1.1.529/Omicron variants as pediatric vaccines for intranasal immunization against HPIV3 and SARS-CoV-2 and characterized these in hamsters. Following intranasal immunization, these B/HPIV3 vectors replicated in the upper and lower respiratory tract and induced mucosal and serum anti-S IgA and IgG. B/HPIV3 expressing ancestral or B.1.617.2/Delta-derived S-6P induced serum antibodies that effectively neutralized SARS-CoV-2 of the ancestral and B.1.617.2/Delta lineages, while the cross-neutralizing potency of B.1.1.529/Omicron S-induced antibodies was lower. Despite the lower cross-neutralizing titers induced by B/HPIV3 expressing S-6P from B.1.1.529/Omicron, a single intranasal dose of all three versions of B/HPIV3 vectors was protective against matched or heterologous WA1/2020, B.1.617.2/Delta or BA.1 (B.1.1.529.1)/Omicron challenge; hamsters were protected from challenge virus replication in the lungs, while low levels of challenge virus were detectable in the upper respiratory tract of a small number of animals. Immunization also protected against lung inflammatory response after challenge, with mild inflammatory cytokine induction associated with the slightly lower level of cross-protection of WA1/2020 and B.1.617.2/Delta variants against the BA.1/Omicron variant. Serum antibodies elicited by all vaccine candidates were broadly reactive against 20 antigenic variants, but the antigenic breadth of antibodies elicited by B/HPIV3-expressed S-6P from the ancestral or B.1.617.2/Delta variant exceeded that of the S-6P B.1.1.529/Omicron expressing vector. These results will guide development of intranasal B/HPIV3 vectors with S antigens matching circulating SARS-CoV-2 variants.

Authors

Institutions

Publication Details

Journal
PLoS Pathogens
Published
2025-04-21
DOI
https://doi.org/10.1371/journal.ppat.1012585
Citations
4
Primary Topic
SARS-CoV-2 and COVID-19 Research
Type
article
Field-Weighted Citation Impact
5.58

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intranasal parainfluenza virus-vectored vaccine expressing SARS-CoV-2 spike protein of Delta or Omicron B.1.1.529 induces mucosal and systemic immunity and protects hamsters against homologous and heterologous challenge

Xueqiao Liu, Yumiko Matsuoka, Peter D. Kwong, Ursula J. Buchholz et al.
4 citations
PLoS Pathogens
SARS-CoV-2 and COVID-19 Research
5.58
article

Intranasal parainfluenza virus-vectored vaccine expressing SARS-CoV-2 spike protein of Delta or Omicron B.1.1.529 induces mucosal and systemic immunity and protects hamsters against homologous and heterologous challenge

Xueqiao Liu, Yumiko Matsuoka, Peter D. Kwong, Ursula J. Buchholz, Hong-Su Park, Cindy Luongo, Cyril Le Nouën, Reed F. Johnson, Jaclyn A. Kaiser, I‐Ting Teng, Lijuan Yang, Celia P. Santos, Eleanor F Duncan
article en
4 citations

Abstract

The continuous emergence of new SARS-CoV-2 variants requires that COVID vaccines be updated to match circulating strains. We generated B/HPIV3-vectored vaccines expressing 6P-stabilized S protein of the ancestral, B.1.617.2/Delta, or B.1.1.529/Omicron variants as pediatric vaccines for intranasal immunization against HPIV3 and SARS-CoV-2 and characterized these in hamsters. Following intranasal immunization, these B/HPIV3 vectors replicated in the upper and lower respiratory tract and induced mucosal and serum anti-S IgA and IgG. B/HPIV3 expressing ancestral or B.1.617.2/Delta-derived S-6P induced serum antibodies that effectively neutralized SARS-CoV-2 of the ancestral and B.1.617.2/Delta lineages, while the cross-neutralizing potency of B.1.1.529/Omicron S-induced antibodies was lower. Despite the lower cross-neutralizing titers induced by B/HPIV3 expressing S-6P from B.1.1.529/Omicron, a single intranasal dose of all three versions of B/HPIV3 vectors was protective against matched or heterologous WA1/2020, B.1.617.2/Delta or BA.1 (B.1.1.529.1)/Omicron challenge; hamsters were protected from challenge virus replication in the lungs, while low levels of challenge virus were detectable in the upper respiratory tract of a small number of animals. Immunization also protected against lung inflammatory response after challenge, with mild inflammatory cytokine induction associated with the slightly lower level of cross-protection of WA1/2020 and B.1.617.2/Delta variants against the BA.1/Omicron variant. Serum antibodies elicited by all vaccine candidates were broadly reactive against 20 antigenic variants, but the antigenic breadth of antibodies elicited by B/HPIV3-expressed S-6P from the ancestral or B.1.617.2/Delta variant exceeded that of the S-6P B.1.1.529/Omicron expressing vector. These results will guide development of intranasal B/HPIV3 vectors with S antigens matching circulating SARS-CoV-2 variants.

PLoS PathogensVol. 21(4)
National Institutes of Health (US), National Institute of Allergy and Infectious Diseases (US)
Division of Intramural Research, National Institute of Allergy and Infectious Diseases, Vaccine Research Center
Good health and well-being
Openalex Percentile: Top 4%
SARS-CoV-2 and COVID-19 Research
5.58
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.