Bromide crossover through various perfluorinated cation-exchange membranes in the presence of two cationic components in solution

Chronoamperometry and steady-state voltammetry data for a specially designed working electrode composed of a Pt disk covered mechanically with various perfluorinated cation-exchange membranes in contact with an external 2 M sulfuric acid solution with addition of various NaBr concentrations have been employed to estimate crossover parameters of bromide ions in relation to redox-flow battery applications. This technically simple but efficient approach has allowed us to determine the values of the diffusion coefficient of the electroactive Br − co-ion inside each membrane and of its equilibrium distribution coefficient between the membrane and the outer solution via an express experimental procedure and subsequent simple calculations. These crossover parameters of bromide co-ions have been found for Nafion NR211, Nafion XL, Nafion NR212, Nafion N115, Nafion N117 as well as GP-IEM-103, GP-IEM-105 membranes. Correlation of the steady-state diffusion-limited current due to the bromide oxidation both with its concentration in the outer solution and with the membrane thickness has been analyzed. It has been established that the transport characteristics of the bromide anion are close to each other for all homogeneous membranes under study in contact with a mixed X M NaBr +2 M H 2 SO 4 solution (the value of X varies between 0.125 and 0.75): their values belong to the range from 2.6 10 −6 cm 2 s −1 to 3.4 10 −6 cm 2 s −1 for its diffusion coefficient inside membrane and to the range from 0.13 to 0.18 for its distribution coefficient at the membrane/solution boundary. Compared to the homogeneous membranes, the Br − anion diffusion inside the heterogenous (Nafion XL) membrane is slower and there is a tendency to its accumulation to a larger amount. Comparison of these results for Nafion NR212 in contact with the NaBr+H 2 SO 4 solution with those previously obtained for the same membrane in contact with the HBr + H 2 SO 4 solution has allowed us to conclude that the applied approximate treatment of experimental data based on the theory of molecular-diffusion transport of this co-ion inside the membrane (without taking into account the migration contribution to the bromide flux owing to the suppression of the electric field by highly mobile H + cations) remains applicable for systems where the NaBr concentration inside the external solution does not exceed 0. 75 M. • Rapid determination of transmembrane-transport parameters of electroactive co-ions. • Specially designed construction: electrode/membrane/solution for chronoamperometry. • Intramembrane diffusion & membrane/solution distribution coefficients found for Br − . • Diffusional permeabilities of various cation-exchange membranes for Br − compared.

Authors

Institutions

Publication Details

Journal
Journal of Electroanalytical Chemistry
Published
2025-04-21
DOI
https://doi.org/10.1016/j.jelechem.2025.119139
Primary Topic
Advanced battery technologies research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bromide crossover through various perfluorinated cation-exchange membranes in the presence of two cationic components in solution

Mikhail A. Vorotyntsev, Olga I. Istakova, Е. В. Золотухина, Dmıtry V. Konev
Journal of Electroanalytical Chemistry
Advanced battery technologies research
article

Bromide crossover through various perfluorinated cation-exchange membranes in the presence of two cationic components in solution

Mikhail A. Vorotyntsev, Olga I. Istakova, Е. В. Золотухина, Dmıtry V. Konev
article en

Abstract

Chronoamperometry and steady-state voltammetry data for a specially designed working electrode composed of a Pt disk covered mechanically with various perfluorinated cation-exchange membranes in contact with an external 2 M sulfuric acid solution with addition of various NaBr concentrations have been employed to estimate crossover parameters of bromide ions in relation to redox-flow battery applications. This technically simple but efficient approach has allowed us to determine the values of the diffusion coefficient of the electroactive Br − co-ion inside each membrane and of its equilibrium distribution coefficient between the membrane and the outer solution via an express experimental procedure and subsequent simple calculations. These crossover parameters of bromide co-ions have been found for Nafion NR211, Nafion XL, Nafion NR212, Nafion N115, Nafion N117 as well as GP-IEM-103, GP-IEM-105 membranes. Correlation of the steady-state diffusion-limited current due to the bromide oxidation both with its concentration in the outer solution and with the membrane thickness has been analyzed. It has been established that the transport characteristics of the bromide anion are close to each other for all homogeneous membranes under study in contact with a mixed X M NaBr +2 M H 2 SO 4 solution (the value of X varies between 0.125 and 0.75): their values belong to the range from 2.6 10 −6 cm 2 s −1 to 3.4 10 −6 cm 2 s −1 for its diffusion coefficient inside membrane and to the range from 0.13 to 0.18 for its distribution coefficient at the membrane/solution boundary. Compared to the homogeneous membranes, the Br − anion diffusion inside the heterogenous (Nafion XL) membrane is slower and there is a tendency to its accumulation to a larger amount. Comparison of these results for Nafion NR212 in contact with the NaBr+H 2 SO 4 solution with those previously obtained for the same membrane in contact with the HBr + H 2 SO 4 solution has allowed us to conclude that the applied approximate treatment of experimental data based on the theory of molecular-diffusion transport of this co-ion inside the membrane (without taking into account the migration contribution to the bromide flux owing to the suppression of the electric field by highly mobile H + cations) remains applicable for systems where the NaBr concentration inside the external solution does not exceed 0. 75 M. • Rapid determination of transmembrane-transport parameters of electroactive co-ions. • Specially designed construction: electrode/membrane/solution for chronoamperometry. • Intramembrane diffusion & membrane/solution distribution coefficients found for Br − . • Diffusional permeabilities of various cation-exchange membranes for Br − compared.

Journal of Electroanalytical ChemistryVol. 988
Frumkin Institute of Physical Chemistry and Electrochemistry Russian Academy of Sciences (RU), Institute of Problems of Chemical Physics (RU)
Russian Science Foundation
Clean water and sanitation
Openalex Percentile: Top 94%
Advanced battery technologies research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.