Measuring the fitted filtration efficiency of cloth masks, medical masks and respirators
Well-fitting 2-layer cotton masks filter in the same range as level 1 masks when worn: around 50%. Level 3 masks and KN95s/KF94s filter around 70%. Over a level 1 mask, external braces or overmasking with a cloth-mask-on-ties produced filtration around 90%. Only N95s and CaN99s, both of which have overhead elastic, performed close to the occupational health and safety standards for fit tested PPE (>99%), filtering at 97-99% when worn, without formal fit testing. These findings inform public health messaging about relative protection from aerosols afforded by different mask types and explain the effectiveness of cloth masks observed in numerous epidemiologic studies conducted in the first year of the pandemic. A plain language summary of these findings is available at https://maskevidence.org/masks-compared.
Authors
- Scott Laengert (ORCID: https://orcid.org/0000-0001-7106-2733)
- Amanda A Tomkins
- Sarah Rassenberg
- Rebecca S. Rudman
- Ken G. Drouillard (ORCID: https://orcid.org/0000-0002-8006-8229)
- Ranmeet Dulai
- Charles‐François de Lannoy (ORCID: https://orcid.org/0000-0001-6451-5626)
- Darren Lawless
- Catherine M. Clase (ORCID: https://orcid.org/0000-0002-4538-5958)
- Gurleen Dulai
- Shiblul Hasan
Institutions
- Queen's University (CA)
- McMaster University Medical Centre (CA)
- University of Windsor (CA)
- McMaster University (CA)
Publication Details
- Journal
- PLoS ONE
- Published
- 2025-04-21
- DOI
- https://doi.org/10.1371/journal.pone.0301310
- Citations
- 2
- Primary Topic
- Infection Control and Ventilation
- Type
- article
- Field-Weighted Citation Impact
- 3.04