Accuracy of an intraoral scanner that uses optical triangulation and confocal microscopy technology for full-arch digital implant impression: in vivo and in vitro evaluation

Background: The purpose of this study was to analyse the accuracy of the full-arch digital implant impressions under both in vivo and in vitro conditions. Methods: A provisional prosthesis was fabricated for a patient with four implants placed in the edentulous maxilla. The master model was obtained using provisional prostheses. Both intraoral scans (IOS group) and extraoral scans (EIOS group) of the master model were performed using an intraoral scanner. The accuracy of the IOS and EIOS groups was calculated for three distances and three angles between the scan bodies (A-B, A-C, and A-D), as well as for the mean deviations of all segments (total deviations). Results: Trueness and precision showed a tendency to decrease as the scanning range increased in both groups. The mean total distance trueness was found to be 121.53±89.55 μm and 57.75±65.17 μm for the IOS group and the EIOS group, respectively (p=.001). The mean total angle trueness was found to be 0.53±0.28 degrees and 0.13±0.09 degrees for the IOS group and the EIOS group, respectively (p

Authors

Institutions

Publication Details

Journal
Selcuk Dental Journal
Published
2025-04-21
DOI
https://doi.org/10.15311/selcukdentj.1524111
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of an intraoral scanner that uses optical triangulation and confocal microscopy technology for full-arch digital implant impression: in vivo and in vitro evaluation

Taygun Sezer, Emir Esim, Erkan Yılmaz
Selcuk Dental Journal
Dental materials and restorations
article

Accuracy of an intraoral scanner that uses optical triangulation and confocal microscopy technology for full-arch digital implant impression: in vivo and in vitro evaluation

Taygun Sezer, Emir Esim, Erkan Yılmaz
article en

Abstract

Background: The purpose of this study was to analyse the accuracy of the full-arch digital implant impressions under both in vivo and in vitro conditions. Methods: A provisional prosthesis was fabricated for a patient with four implants placed in the edentulous maxilla. The master model was obtained using provisional prostheses. Both intraoral scans (IOS group) and extraoral scans (EIOS group) of the master model were performed using an intraoral scanner. The accuracy of the IOS and EIOS groups was calculated for three distances and three angles between the scan bodies (A-B, A-C, and A-D), as well as for the mean deviations of all segments (total deviations). Results: Trueness and precision showed a tendency to decrease as the scanning range increased in both groups. The mean total distance trueness was found to be 121.53±89.55 μm and 57.75±65.17 μm for the IOS group and the EIOS group, respectively (p=.001). The mean total angle trueness was found to be 0.53±0.28 degrees and 0.13±0.09 degrees for the IOS group and the EIOS group, respectively (p

Selcuk Dental JournalVol. 12(1)
Yozgat Bozok Üniversitesi (TR)
Openalex Percentile: Top 92%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.