Long-Term Safety of “4-Hour” Hemoadsorption Combined with Hemodialysis in Maintenance Hemodialysis Patients: A Multicenter Prospective Cohort Study
Extending HA duration to 4 h with high-flow hemodynamics (Qb >250 mL/min) is safe and enhances toxin clearance without increasing clotting risks. These findings challenge current SOP limitations on HA duration and support protocol optimization in maintenance HD patients.
Authors
- Jingxin Zhao (ORCID: https://orcid.org/0000-0002-5385-3969)
- Yangyang Shen (ORCID: https://orcid.org/0000-0002-8177-4766)
- Xiaofei Wang (ORCID: https://orcid.org/0000-0001-7731-0339)
- Yuanyuan Li (ORCID: https://orcid.org/0000-0001-9061-6885)
- Dongliang Zhang (ORCID: https://orcid.org/0000-0003-3932-3723)
- Zuo‐Feng Zhang (ORCID: https://orcid.org/0000-0002-4669-3995)
- Yanjun Gao (ORCID: https://orcid.org/0000-0002-0496-0055)
- Cuiping Liu (ORCID: https://orcid.org/0000-0002-7383-1505)
- Tao Yang
- Hongjuan Zhang (ORCID: https://orcid.org/0009-0000-5734-7214)
Institutions
- Peking University (CN)
- China Rehabilitation Research Center (CN)
- Beijing Jishuitan Hospital (CN)
- Beijing Geriatric Hospital (CN)
- Beijing Chang'an Integrated Traditional Chinese and Western Medicine Hospital (CN)
Publication Details
- Journal
- Blood Purification
- Published
- 2025-04-21
- DOI
- https://doi.org/10.1159/000545988
- Citations
- 3
- Primary Topic
- Dialysis and Renal Disease Management
- Type
- article
- Field-Weighted Citation Impact
- 4.29