Cryoballoon Ablation With the POLARx FIT or the Arctic Front Advance Pro for Paroxysmal Atrial Fibrillation: A Health Economic Analysis

Background: Pulmonary vein isolation (PVI) is the main ablation strategy for the treatment of paroxysmal atrial fibrillation. Different technologies are available for PVI, including various cryoballoon catheters (CB-A). Compared with the Arctic Front Advance Pro™, the novel POLARx FIT™ CB-A might reduce costs for atrial fibrillation ablation. Objective: The aim of this study is to perform a health economic evaluation of two cryoballoon systems for PVI procedures. Methods: All patients undergoing their first PVI procedure with POLARx FIT™ CB-A or the Arctic Front Advance Pro™ CB-A were prospectively enrolled. The health economic analysis was performed on the index hospitalization and procedure. The primary safety endpoint included procedure-related adverse events within the index hospitalization. A decision tree model was built to estimate downstream costs. Results: A total of 80 patients with paroxysmal atrial fibrillation undergoing PVI were analyzed, with 40 patients in each arm. Compared with the Arctic Front Advance Pro™ CB-A, POLARx FIT™ CB-A showed a lower procedure time, left-atrium dwell time, and fluoroscopy time. The complication rate was low (6.3%) and included 3 reversible phrenic nerve palsies in the POLARx FIT™ CB-A group vs 2 in the Arctic Front Advance Pro™ CB-A group. Compared with the Arctic Front Advance Pro, the POLARx FIT™ CB-A was associated with lower procedural costs (€2069.7 ± €165.2 vs €2239.5 ± €366.0; P =.009). Conclusion: The POLARx FIT™ CB-A was associated with a shorter procedure time, translating into lower procedural costs, compared with the Arctic Front Advance Pro. Complications were rare and comparable between the two technologies.

Authors

Publication Details

Journal
Journal of health economics and outcomes research
Published
2025-01-01
DOI
https://doi.org/10.36469/jheor.2025.133233
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cryoballoon Ablation With the POLARx FIT or the Arctic Front Advance Pro for Paroxysmal Atrial Fibrillation: A Health Economic Analysis

Ali Gharaviri, Carlo de Asmundis, Steffen Uffenorde, Antonio Sorgente et al.
Journal of health economics and outcomes research
Atrial Fibrillation Management and Outcomes
article

Cryoballoon Ablation With the POLARx FIT or the Arctic Front Advance Pro for Paroxysmal Atrial Fibrillation: A Health Economic Analysis

Ali Gharaviri, Carlo de Asmundis, Steffen Uffenorde, Antonio Sorgente, Ingrid Overeinder, Erwin Ströker, Luigi Pannone, Mark La Meir, Gezim Bala, Gian‐Battista Chierchia, Pasquale Vergara, Alvise Del Monte, Andrea Sarkozy, Ioannis Doundoulakis, Domenico Giovanni Della Rocca, Giacomo Talevi, Alexandre Almorad, Juan Sieira, Pedro Brugada, Antonia Bosworth Smith
article en

Abstract

Background: Pulmonary vein isolation (PVI) is the main ablation strategy for the treatment of paroxysmal atrial fibrillation. Different technologies are available for PVI, including various cryoballoon catheters (CB-A). Compared with the Arctic Front Advance Pro™, the novel POLARx FIT™ CB-A might reduce costs for atrial fibrillation ablation. Objective: The aim of this study is to perform a health economic evaluation of two cryoballoon systems for PVI procedures. Methods: All patients undergoing their first PVI procedure with POLARx FIT™ CB-A or the Arctic Front Advance Pro™ CB-A were prospectively enrolled. The health economic analysis was performed on the index hospitalization and procedure. The primary safety endpoint included procedure-related adverse events within the index hospitalization. A decision tree model was built to estimate downstream costs. Results: A total of 80 patients with paroxysmal atrial fibrillation undergoing PVI were analyzed, with 40 patients in each arm. Compared with the Arctic Front Advance Pro™ CB-A, POLARx FIT™ CB-A showed a lower procedure time, left-atrium dwell time, and fluoroscopy time. The complication rate was low (6.3%) and included 3 reversible phrenic nerve palsies in the POLARx FIT™ CB-A group vs 2 in the Arctic Front Advance Pro™ CB-A group. Compared with the Arctic Front Advance Pro, the POLARx FIT™ CB-A was associated with lower procedural costs (€2069.7 ± €165.2 vs €2239.5 ± €366.0; P =.009). Conclusion: The POLARx FIT™ CB-A was associated with a shorter procedure time, translating into lower procedural costs, compared with the Arctic Front Advance Pro. Complications were rare and comparable between the two technologies.

Journal of health economics and outcomes research
Pfizer, AtriCure, Boston Scientific Corporation, Daiichi-Sankyo, MicroPort, Biosense Webster, Daiichi Sankyo Europe
Openalex Percentile: Top 86%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines