Abstract 4684: An in vivo comparison of 137Cs and orthovoltage irradiation for murine bone marrow transplantation

Total body irradiation for bone marrow transplantation (BMT) conditioning is commonly used in immunologic research. Historically, cesium-137 (137Cs) irradiators were predominantly used as a radiation source for these studies. However, 137Cs has a moderate half-life (30 years), is highly water soluble, and poses significant environmental and radiological safety concerns. As a result, the Department of Energy is promoting the replacement of 137Cs irradiation systems with orthovoltage x-ray cabinet systems, which pose no such concerns. Because the physical characteristics of x-ray and 137Cs photon beams have slightly different energy deposition characteristics, the relatively biological effectiveness (RBE) for x-rays is slightly higher than 137Cs in cell survival studies. This study aims to compare the RBE of orthovoltage and 137Cs irradiators with regards to BMT efficiency. Total body irradiation was performed on C57BL6 mice using 137Cs or 320 kVp x-rays across six dose levels to establish a RBE for lethality. Cohorts of five mice were irradiated using split-dose radiation delivered four hours apart. Daily observations and body weights were captured over a 30-day period. Mice with poor body condition scores or weight loss ≥20% were euthanized. With x-rays, 50% lethality was observed ∼750 cGy while 137Cs required ∼850 cGy, which results in an RBE of 750 cGy/850 cGy = 0.88. Bone marrow ablation and subsequent engraftment efficacy was compared in a parallel study. Cohorts of five C57BL6 CD45.1 recipient mice received total body irradiation with an established single dose 1000 cGy 137Cs regimen or a range of x-ray doses (910-1030 cGy single-dose) and then were infused with CD45.2 donor bone marrow. Ten weeks after BMT, bone marrow, spleen, thymus, and peripheral blood were analyzed via multi-color flow cytometry and the percentage of CD45.1 and CD45.2-positive cells were analyzed to determine marrow engraftment efficiency across various immune compartments. A clear dose-response relationship with bone marrow ablation and engraftment was observed in the stem cell and progenitor compartments. LSK (Lineage- Sca-1+ c-Kit+) cells and other hematopoietic progenitors in the bone marrow were efficiently engrafted (>99%) except for the lowest dose of 910 cGy (around 98%). Similarly, in the spleen, B cells, myeloid, megakaryocyte/erythrocyte, and granulocyte/macrophage lineages were also efficiently engrafted similar to that of 137Cs. Developing thymocytes were efficiently replaced by all radiation regimens, while replacement of peripheral T cell populations varied but were similar to traditional 137Cs at the highest doses. Taken together, these data demonstrate comparable BMT efficiencies with orthovoltage irradiation after appropriate dose-optimization. Citation Format: Danielle M. Burgenske, Brett L. Carlson, Matthew J. Rajcula, Michael J. Shapiro, Virginia M. Shapiro, Jann N. Sarkaria. An in vivo comparison of 137Cs and orthovoltage irradiation for murine bone marrow transplantation [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2025; Part 1 (Regular Abstracts); 2025 Apr 25-30; Chicago, IL. Philadelphia (PA): AACR; Cancer Res 2025;85(8_Suppl_1):Abstract nr 4684.

Authors

Institutions

Publication Details

Journal
Cancer Research
Published
2025-04-21
DOI
https://doi.org/10.1158/1538-7445.am2025-4684
Primary Topic
Medical Imaging and Pathology Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4684: An in vivo comparison of 137Cs and orthovoltage irradiation for murine bone marrow transplantation

Michael J. Shapiro, Jann Nagina Sarkaria, Virginia Smith Shapiro, Danielle M. Burgenske et al.
Cancer Research
Medical Imaging and Pathology Studies
article

Abstract 4684: An in vivo comparison of 137Cs and orthovoltage irradiation for murine bone marrow transplantation

Michael J. Shapiro, Jann Nagina Sarkaria, Virginia Smith Shapiro, Danielle M. Burgenske, Brett L. Carlson, Matthew Rajcula
article en

Abstract

Total body irradiation for bone marrow transplantation (BMT) conditioning is commonly used in immunologic research. Historically, cesium-137 (137Cs) irradiators were predominantly used as a radiation source for these studies. However, 137Cs has a moderate half-life (30 years), is highly water soluble, and poses significant environmental and radiological safety concerns. As a result, the Department of Energy is promoting the replacement of 137Cs irradiation systems with orthovoltage x-ray cabinet systems, which pose no such concerns. Because the physical characteristics of x-ray and 137Cs photon beams have slightly different energy deposition characteristics, the relatively biological effectiveness (RBE) for x-rays is slightly higher than 137Cs in cell survival studies. This study aims to compare the RBE of orthovoltage and 137Cs irradiators with regards to BMT efficiency. Total body irradiation was performed on C57BL6 mice using 137Cs or 320 kVp x-rays across six dose levels to establish a RBE for lethality. Cohorts of five mice were irradiated using split-dose radiation delivered four hours apart. Daily observations and body weights were captured over a 30-day period. Mice with poor body condition scores or weight loss ≥20% were euthanized. With x-rays, 50% lethality was observed ∼750 cGy while 137Cs required ∼850 cGy, which results in an RBE of 750 cGy/850 cGy = 0.88. Bone marrow ablation and subsequent engraftment efficacy was compared in a parallel study. Cohorts of five C57BL6 CD45.1 recipient mice received total body irradiation with an established single dose 1000 cGy 137Cs regimen or a range of x-ray doses (910-1030 cGy single-dose) and then were infused with CD45.2 donor bone marrow. Ten weeks after BMT, bone marrow, spleen, thymus, and peripheral blood were analyzed via multi-color flow cytometry and the percentage of CD45.1 and CD45.2-positive cells were analyzed to determine marrow engraftment efficiency across various immune compartments. A clear dose-response relationship with bone marrow ablation and engraftment was observed in the stem cell and progenitor compartments. LSK (Lineage- Sca-1+ c-Kit+) cells and other hematopoietic progenitors in the bone marrow were efficiently engrafted (>99%) except for the lowest dose of 910 cGy (around 98%). Similarly, in the spleen, B cells, myeloid, megakaryocyte/erythrocyte, and granulocyte/macrophage lineages were also efficiently engrafted similar to that of 137Cs. Developing thymocytes were efficiently replaced by all radiation regimens, while replacement of peripheral T cell populations varied but were similar to traditional 137Cs at the highest doses. Taken together, these data demonstrate comparable BMT efficiencies with orthovoltage irradiation after appropriate dose-optimization. Citation Format: Danielle M. Burgenske, Brett L. Carlson, Matthew J. Rajcula, Michael J. Shapiro, Virginia M. Shapiro, Jann N. Sarkaria. An in vivo comparison of 137Cs and orthovoltage irradiation for murine bone marrow transplantation [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2025; Part 1 (Regular Abstracts); 2025 Apr 25-30; Chicago, IL. Philadelphia (PA): AACR; Cancer Res 2025;85(8_Suppl_1):Abstract nr 4684.

Cancer ResearchVol. 85(8_Supplement_1)
Mayo Clinic in Arizona (US)
Openalex Percentile: Top 87%
Medical Imaging and Pathology Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.