Analysis of Power Transformer Insulation Resistance Using the Applied Voltage test Method

This study investigates insulation resistance failures in newly manufactured power transformers at PT XYZ, focusing on the application of Applied Voltage Test as the main method to detect potential insulation failures. Different from previous studies that focus more on transformers that have been in operation for a long time, this study identifies that insulation failure in new transformers can be caused by production factors, such as insulation paper degradation due to exposure to temperature and humidity during the manufacturing process. The research was conducted through direct observation, structured interviews with testing technicians, and comparative analysis of two transformer units. The test results showed significant differences between the two units, where Transformer Unit 2 failed the test due to insulation paper degradation, which was confirmed through physical inspection. This study emphasizes the importance of Applied Voltage Test in identifying insulation defects at an early stage and shows that the quality of materials and production processes greatly affect the reliability of transformers. The findings make new contributions to understanding the causes of insulation failures in new transformers, as well as provide practical recommendations for optimization of test methods and improvement of production quality, thereby minimizing the risk of insulation failures in new transformers. Furthermore, this research highlights the significance of early detection through Polarization Index testing, which can serve as an indicator of insulation degradation. These insights are crucial for improving quality control in transformer manufacturing and ensuring the reliability of power distribution systems.

Authors

Publication Details

Journal
ELKHA
Published
2025-04-21
DOI
https://doi.org/10.26418/elkha.v17i1.90883
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Power Transformer Insulation Resistance Using the Applied Voltage test Method

Shazana Dhiya Ayuni, Jamaaluddin Jamaaluddin, Mohammad Feri
3 links
ELKHA
Power Transformer Diagnostics and Insulation
article

Analysis of Power Transformer Insulation Resistance Using the Applied Voltage test Method

Shazana Dhiya Ayuni, Jamaaluddin Jamaaluddin, Mohammad Feri
article en

Abstract

This study investigates insulation resistance failures in newly manufactured power transformers at PT XYZ, focusing on the application of Applied Voltage Test as the main method to detect potential insulation failures. Different from previous studies that focus more on transformers that have been in operation for a long time, this study identifies that insulation failure in new transformers can be caused by production factors, such as insulation paper degradation due to exposure to temperature and humidity during the manufacturing process. The research was conducted through direct observation, structured interviews with testing technicians, and comparative analysis of two transformer units. The test results showed significant differences between the two units, where Transformer Unit 2 failed the test due to insulation paper degradation, which was confirmed through physical inspection. This study emphasizes the importance of Applied Voltage Test in identifying insulation defects at an early stage and shows that the quality of materials and production processes greatly affect the reliability of transformers. The findings make new contributions to understanding the causes of insulation failures in new transformers, as well as provide practical recommendations for optimization of test methods and improvement of production quality, thereby minimizing the risk of insulation failures in new transformers. Furthermore, this research highlights the significance of early detection through Polarization Index testing, which can serve as an indicator of insulation degradation. These insights are crucial for improving quality control in transformer manufacturing and ensuring the reliability of power distribution systems.

ELKHAVol. 17(1)
Openalex Percentile: Top 94%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.