Sparse and transferable three-dimensional dynamic vascular reconstruction for instantaneous diagnosis

Three-dimensional (3D) structural information of cardiac vessels is crucial for the diagnosis and treatment of cardiovascular disease. In clinical practice, interventionalists have to empirically infer 3D cardiovascular topology from multi-view X-ray angiography images, which is time-consuming and requires extensive experience. Owing to the dynamic nature of heartbeats and sparse-view observations in clinical practice, accurate and efficient reconstruction of 3D cardiovascular structures from X-ray angiography images remains challenging. Here we introduce AutoCAR, a fully automated transfer learning-based algorithm for dynamic 3D cardiovascular reconstruction. AutoCAR comprises three main components: pose domain adaptation, sparse backwards projection and vascular graph optimization. By merging the X-ray angiography imaging parameter statistics of over 1,000 clinical cases into synthetic data generation, and exploiting the intrinsic spatial sparsity of cardiac vessels for computational design, AutoCAR outperforms state-of-the-art methods in both qualitative and quantitative evaluations, enabling dynamic cardiovascular reconstruction in real-world clinical settings. We envision that AutoCAR will facilitate current diagnostic and intervention procedures and pave the way for real-time visual guidance and autonomous catheter navigation in cardiac intervention. Yinheng Zhu et al. present AutoCAR, an automated algorithm for reconstructing three-dimensional cardiovascular structures from X-ray images. It uses transfer learning and vascular graph optimization to achieve high efficiency and accuracy, with the goal to enable medical procedures and diagnosis in real-world settings.

Authors

Institutions

Publication Details

Journal
Nature Machine Intelligence
Published
2025-04-21
DOI
https://doi.org/10.1038/s42256-025-01025-7
Citations
3
Primary Topic
Anatomy and Medical Technology
Type
article
Field-Weighted Citation Impact
2.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sparse and transferable three-dimensional dynamic vascular reconstruction for instantaneous diagnosis

Yinheng Zhu, H. Liu, Shaohua Ma, Yong Wang et al.
3 citations
Nature Machine Intelligence
Anatomy and Medical Technology
2.02
article

Sparse and transferable three-dimensional dynamic vascular reconstruction for instantaneous diagnosis

Yinheng Zhu, H. Liu, Shaohua Ma, Yong Wang, Chunxia Di, Fangzhou Liao
article en
3 citations

Abstract

Three-dimensional (3D) structural information of cardiac vessels is crucial for the diagnosis and treatment of cardiovascular disease. In clinical practice, interventionalists have to empirically infer 3D cardiovascular topology from multi-view X-ray angiography images, which is time-consuming and requires extensive experience. Owing to the dynamic nature of heartbeats and sparse-view observations in clinical practice, accurate and efficient reconstruction of 3D cardiovascular structures from X-ray angiography images remains challenging. Here we introduce AutoCAR, a fully automated transfer learning-based algorithm for dynamic 3D cardiovascular reconstruction. AutoCAR comprises three main components: pose domain adaptation, sparse backwards projection and vascular graph optimization. By merging the X-ray angiography imaging parameter statistics of over 1,000 clinical cases into synthetic data generation, and exploiting the intrinsic spatial sparsity of cardiac vessels for computational design, AutoCAR outperforms state-of-the-art methods in both qualitative and quantitative evaluations, enabling dynamic cardiovascular reconstruction in real-world clinical settings. We envision that AutoCAR will facilitate current diagnostic and intervention procedures and pave the way for real-time visual guidance and autonomous catheter navigation in cardiac intervention. Yinheng Zhu et al. present AutoCAR, an automated algorithm for reconstructing three-dimensional cardiovascular structures from X-ray images. It uses transfer learning and vascular graph optimization to achieve high efficiency and accuracy, with the goal to enable medical procedures and diagnosis in real-world settings.

Nature Machine IntelligenceVol. 7(5)
Chinese PLA General Hospital (CN), Shunyi Hospital of Beijing Traditional Chinese Medicine Hospital (CN), Tsinghua–Berkeley Shenzhen Institute (CN), Tsinghua University (CN)
Natural Science Foundation of Guangdong Province, National Natural Science Foundation of China-Yunnan Joint Fund
Openalex Percentile: Top 14%
Anatomy and Medical Technology
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.