Performance Assessment for Automatic Generation Control via Dynamic Models Identified From Extracted Data Segments

ABSTRACT Automatic generation control (AGC) systems in thermal generation units keep the generated active power tracking the AGC commands dispatched from dispatching departments of power grids. The AGC performance of generation units is crucial for power grids to maintain their electrical energy balance and is of high concern to power plants and power grids. The problem is to estimate the ramp rate and static deviation as two AGC performance metrics from desired and generated active powers. This paper proposes an AGC performance assessment method to address two challenges in estimating the two performance metrics. One challenge is that not all data segments of the desired active power with amplitude variations are suitable for performance assessment. Another challenge is that severe noise induces uncertainties in the estimates of performance metrics. For the first challenge, the proposed method extracts step‐pattern data segments, from which dynamic models are identified and performance metrics are estimated from model step responses. For the second challenge, uncertainties of the estimated performance metrics are quantified by confidence intervals obtained from the dynamic models with surrogate parameters. The benefits of the proposed method over the existing ones include: (1) invalid estimates are avoided by selecting step‐pattern data segments for AGC performance assessment; (2) the root mean squared estimation errors are reduced by more than 60% in typical examples; (3) the uncertainties in the estimates are quantified by their confidence intervals. Numerical and industrial examples are provided to illustrate the effectiveness and benefits of the proposed method.

Authors

Institutions

Publication Details

Journal
Energy Science & Engineering
Published
2025-04-21
DOI
https://doi.org/10.1002/ese3.70106
Citations
1
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Assessment for Automatic Generation Control via Dynamic Models Identified From Extracted Data Segments

Xiangkun Pang, Song Gao, Jiandong Wang, Zijiang Yang
1 citations
Energy Science & Engineering
Frequency Control in Power Systems
0.73
article

Performance Assessment for Automatic Generation Control via Dynamic Models Identified From Extracted Data Segments

Xiangkun Pang, Song Gao, Jiandong Wang, Zijiang Yang
article en
1 citations

Abstract

ABSTRACT Automatic generation control (AGC) systems in thermal generation units keep the generated active power tracking the AGC commands dispatched from dispatching departments of power grids. The AGC performance of generation units is crucial for power grids to maintain their electrical energy balance and is of high concern to power plants and power grids. The problem is to estimate the ramp rate and static deviation as two AGC performance metrics from desired and generated active powers. This paper proposes an AGC performance assessment method to address two challenges in estimating the two performance metrics. One challenge is that not all data segments of the desired active power with amplitude variations are suitable for performance assessment. Another challenge is that severe noise induces uncertainties in the estimates of performance metrics. For the first challenge, the proposed method extracts step‐pattern data segments, from which dynamic models are identified and performance metrics are estimated from model step responses. For the second challenge, uncertainties of the estimated performance metrics are quantified by confidence intervals obtained from the dynamic models with surrogate parameters. The benefits of the proposed method over the existing ones include: (1) invalid estimates are avoided by selecting step‐pattern data segments for AGC performance assessment; (2) the root mean squared estimation errors are reduced by more than 60% in typical examples; (3) the uncertainties in the estimates are quantified by their confidence intervals. Numerical and industrial examples are provided to illustrate the effectiveness and benefits of the proposed method.

Energy Science & EngineeringVol. 13(6)
State Grid Corporation of China (China) (CN), Shandong University of Science and Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 29%
Frequency Control in Power Systems
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.