Detection of blood glucose based on the aggregation induced luminescence effect in 4-formyl-3-hydroxybenzoic acid@ZIF-8 and a ratiometric fluorescence method based on Förster resonance energy transfer between aggregation-induced emission molecules an

A novel and simple ratiometric fluorescence detection method for H<sub>2</sub>O<sub>2</sub> and glucose was proposed on the basis of the aggregation-induced luminescence effect of the aggregation-induced emission (AIE) molecule 4-formyl-3-hydroxybenzoic acid (FHBA) in ZIF-8 and the mechanism of fluorescence resonance energy transfer (FRET) between the complex FHBA@ZIF-8 and diallyl phthalate (DAP). First, glucose was oxidized to H<sub>2</sub>O<sub>2</sub> under the catalysis of glucose oxidase. In the presence of horseradish peroxidase, the latter further oxidized <i>o</i>-phenylenediamine to produce yellow fluorescent DAP with an emission wavelength of 560 nm. The fluorescence of FHBA@ZIF-8 at 445 nm can be effectively quenched because the ultraviolet absorption spectrum of DAP overlaps well with the emission spectrum of FHBA@ZIF-8. Therefore, a highly sensitive ratiometric fluorescence detection method for detecting H<sub>2</sub>O<sub>2</sub> and glucose was constructed using the change in the ratio of fluorescence intensity at two wavelengths (<i>F</i><sub>560</sub>/<i>F</i><sub>445</sub>). The linear range of H<sub>2</sub>O<sub>2</sub> detection by this method is 1-150 μM, and the detection limit is 0.21 μM. The linear range of glucose detection is 1-100 μM, and the detection limit is 0.17 μM. The method was successfully applied for the detection of glucose in human serum samples, and it has broad potential in clinical diagnosis and research.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-01-01
DOI
https://doi.org/10.1039/d4ay02325k
Primary Topic
Molecular Sensors and Ion Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of blood glucose based on the aggregation induced luminescence effect in 4-formyl-3-hydroxybenzoic acid@ZIF-8 and a ratiometric fluorescence method based on Förster resonance energy transfer between aggregation-induced emission molecules an

Yaodong Zhang, Jing Li, Xu Xu
Analytical Methods
Molecular Sensors and Ion Detection
article

Detection of blood glucose based on the aggregation induced luminescence effect in 4-formyl-3-hydroxybenzoic acid@ZIF-8 and a ratiometric fluorescence method based on Förster resonance energy transfer between aggregation-induced emission molecules an

Yaodong Zhang, Jing Li, Xu Xu
article en

Abstract

A novel and simple ratiometric fluorescence detection method for H<sub>2</sub>O<sub>2</sub> and glucose was proposed on the basis of the aggregation-induced luminescence effect of the aggregation-induced emission (AIE) molecule 4-formyl-3-hydroxybenzoic acid (FHBA) in ZIF-8 and the mechanism of fluorescence resonance energy transfer (FRET) between the complex FHBA@ZIF-8 and diallyl phthalate (DAP). First, glucose was oxidized to H<sub>2</sub>O<sub>2</sub> under the catalysis of glucose oxidase. In the presence of horseradish peroxidase, the latter further oxidized <i>o</i>-phenylenediamine to produce yellow fluorescent DAP with an emission wavelength of 560 nm. The fluorescence of FHBA@ZIF-8 at 445 nm can be effectively quenched because the ultraviolet absorption spectrum of DAP overlaps well with the emission spectrum of FHBA@ZIF-8. Therefore, a highly sensitive ratiometric fluorescence detection method for detecting H<sub>2</sub>O<sub>2</sub> and glucose was constructed using the change in the ratio of fluorescence intensity at two wavelengths (<i>F</i><sub>560</sub>/<i>F</i><sub>445</sub>). The linear range of H<sub>2</sub>O<sub>2</sub> detection by this method is 1-150 μM, and the detection limit is 0.21 μM. The linear range of glucose detection is 1-100 μM, and the detection limit is 0.17 μM. The method was successfully applied for the detection of glucose in human serum samples, and it has broad potential in clinical diagnosis and research.

Analytical MethodsVol. 17(26)
Shaanxi Normal University (CN)
Affordable and clean energy
Openalex Percentile: Top 92%
Molecular Sensors and Ion Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.